• 使用MegaCli监控Linux硬盘


    1.首先查看机器是否使用的是MegaRAID卡

    dmesg | grep RAID
    [    6.932741] scsi host0: Avago SAS based MegaRAID driver
    

    2.添加 megaraid 源:

    修改 /etc/apt/sources.list 在末尾添加

    deb http://hwraid.le-vert.net/ubuntu precise main
    

    然后执行:

    apt-get update
    apt-get install megacli megactl megaraid-status
    

    如果执行提示 GPG 错误,需要执行如下命令添加证书:

    wget -O - http://hwraid.le-vert.net/debian/hwraid.le-vert.net.gpg.key | sudo apt-key add -
    

    然后再次执行:

    apt-get install megacli megactl megaraid-status
    

    3.使用megacli命令进行一些简单的查询

    <i>显示所有RAID级别、设置及逻辑盘信息

    sudo megacli -LDInfo -Lall -aALL 
    

    输出

                                         
    Adapter 0 -- Virtual Drive Information:
    Virtual Drive: 0 (Target Id: 0)
    Name                :
    RAID Level          : Primary-1, Secondary-0, RAID Level Qualifier-0
    Size                : 1.090 TB
    Sector Size         : 512
    Is VD emulated      : No
    Mirror Data         : 1.090 TB
    State               : Optimal
    Strip Size          : 64 KB
    Number Of Drives    : 2
    Span Depth          : 1
    Default Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
    Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU
    Default Access Policy: Read/Write
    Current Access Policy: Read/Write
    Disk Cache Policy   : Disk's Default
    Encryption Type     : None
    Default Power Savings Policy: Controller Defined
    Current Power Savings Policy: None
    Can spin up in 1 minute: Yes
    LD has drives that support T10 power conditions: Yes
    LD's IO profile supports MAX power savings with cached writes: No
    Bad Blocks Exist: No
    Is VD Cached: No
    
    
    
    Exit Code: 0x00
    

    <ii>显示所有的物理信息

    sudo megacli -PDList -aAll
    

    过滤输出

    sudo megacli -PDList -aAll  | grep "Firmware state|Slot Number|Error"
    

     参考输出

    Enclosure Device ID: 32
    Slot Number: 11
    Enclosure position: 1
    Device Id: 11
    WWN: 50000397eb88257a
    Sequence Number: 2
    Media Error Count: 0
    Other Error Count: 4
    Predictive Failure Count: 0
    Last Predictive Failure Event Seq Number: 0
    PD Type: SATA
    
    Raw Size: 7.277 TB [0x3a3812ab0 Sectors]
    Non Coerced Size: 7.276 TB [0x3a3712ab0 Sectors]
    Coerced Size: 7.276 TB [0x3a3700000 Sectors]
    Sector Size:  512
    Logical Sector Size:  512
    Physical Sector Size:  4096
    Firmware state: JBOD
    Device Firmware Level: GX4D
    Shield Counter: 0
    Successful diagnostics completion on :  N/A
    SAS Address(0): 0x500056b3295a37cb
    Connected Port Number: 0(path0) 
    Inquiry Data:         77N4K3BIFYRDTOSHIBA MG05ACA800E                         GX4D
    FDE Capable: Not Capable
    FDE Enable: Disable
    Secured: Unsecured
    Locked: Unlocked
    Needs EKM Attention: No
    Foreign State: None 
    Device Speed: 6.0Gb/s 
    Link Speed: 6.0Gb/s 
    Media Type: Hard Disk Device
    Drive Temperature :28C (82.40 F)
    PI Eligibility:  No 
    Drive is formatted for PI information:  No
    PI: No PI
    Drive's NCQ setting : N/A
    Port-0 :
    Port status: Active
    Port's Linkspeed: 6.0Gb/s 
    Drive has flagged a S.M.A.R.T alert : No
    
    
    
    Enclosure Device ID: 32
    Slot Number: 12
    Drive's position: DiskGroup: 0, Span: 0, Arm: 0
    Enclosure position: 1
    Device Id: 12
    WWN: 5000CCA02D78FCDB
    Sequence Number: 2
    Media Error Count: 0
    Other Error Count: 0
    Predictive Failure Count: 0
    Last Predictive Failure Event Seq Number: 0
    PD Type: SAS
    
    Raw Size: 1.090 TB [0x8bba0cb0 Sectors]
    Non Coerced Size: 1.090 TB [0x8baa0cb0 Sectors]
    Coerced Size: 1.090 TB [0x8ba80000 Sectors]
    Sector Size:  512
    Logical Sector Size:  512
    Physical Sector Size:  512
    Firmware state: Online, Spun Up
    Device Firmware Level: FU29
    Shield Counter: 0
    Successful diagnostics completion on :  N/A
    SAS Address(0): 0x5000cca02d78fcd9
    SAS Address(1): 0x0
    Connected Port Number: 0(path0) 
    Inquiry Data: HGST    HUC101812CSS200 FU2906J4JPYZ            
    FDE Capable: Not Capable
    FDE Enable: Disable
    Secured: Unsecured
    Locked: Unlocked
    Needs EKM Attention: No
    Foreign State: None 
    Device Speed: 12.0Gb/s 
    Link Speed: 12.0Gb/s 
    Media Type: Hard Disk Device
    Drive Temperature :55C (131.00 F)
    PI Eligibility:  No 
    Drive is formatted for PI information:  Yes 
    PI: PI with type 2
    Port-0 :
    Port status: Active
    Port's Linkspeed: 12.0Gb/s 
    Port-1 :
    Port status: Active
    Port's Linkspeed: 12.0Gb/s 
    Drive has flagged a S.M.A.R.T alert : No
    