• mysql主从同步因断电产生的不能同步问题


    偶尔因为断电导致mysql slave 出现复制错误“Could not parse relay log event entry”

    Could not parse relay log event entry. The possible reasons are: the master's binary log is corrupted (you can check this by running 'mysqlbinlog' on the binary log), the slave's relay log is corrupted (you can check this by running 'mysqlbinlog' on the relay log), a network problem, or a bug in the master's or slave's MySQL code. If you want to check the master's binary log or slave's relay log, you will be able to know their names by issuing 'SHOW SLAVE STATUS' on this slave.

    先查询下状态

    show slave status G

    Master_Host: 192.168.2.51

                    Master_User: backupuser

                    Master_Port: 3306

                  Connect_Retry: 60

                Master_Log_File: mysql-bin.000078

            Read_Master_Log_Pos: 984673998

                 Relay_Log_File: memcached-relay-bin.000039

                  Relay_Log_Pos: 747157846

          Relay_Master_Log_File: mysql-bin.000078

               Slave_IO_Running: Yes

              Slave_SQL_Running: No

              Skip_Counter: 0

            Exec_Master_Log_Pos: 747157709

                Relay_Log_Space: 984679197

    如果可以确定主服务器没有问题的话,那么重置下从服务器的同步位置就可以了。

    如上可以对应的指令为:

    stop slave;

    CHANGE MASTER TO  MASTER_LOG_FILE = 'mysql-bin.000078', MASTER_LOG_POS =747157709;

    start slave;

    再用 show slave status G 查看状态。如下:

    Master_Log_File: mysql-bin.000078

            Read_Master_Log_Pos: 879029246

                 Relay_Log_File: memcached-relay-bin.000002

                  Relay_Log_Pos: 1336369

          Relay_Master_Log_File: mysql-bin.000078

               Slave_IO_Running: Yes

              Slave_SQL_Running: Yes

                Replicate_Do_DB: 

            Replicate_Ignore_DB: 

             Replicate_Do_Table: 

         Replicate_Ignore_Table: 

        Replicate_Wild_Do_Table: 

    Replicate_Wild_Ignore_Table: 

                     Last_Errno: 0

                     Last_Error: 

                   Skip_Counter: 0

            Exec_Master_Log_Pos: 748493843

                Relay_Log_Space: 131871772

                Until_Condition: None

                 Until_Log_File: 

                  Until_Log_Pos: 0

             Master_SSL_Allowed: No

             Master_SSL_CA_File: 

             Master_SSL_CA_Path: 

                Master_SSL_Cert: 

              Master_SSL_Cipher: 

                 Master_SSL_Key: 

          Seconds_Behind_Master: 339469

    好了到现在搞定了。

    还有说法是内存不够用产生的,有人清除了几个不用的进程释放内存后, stop slave; start slave;然后好了,我遇到的不是这个情况,如果你遇到了,按我上面的不能解决的话,可以试着释放内存看看。

  • 相关阅读:
    洛谷P1880 石子合并
    洛谷P3265 装备购买
    bzoj1345 序列问题
    从群里抄来的某题
    poj2689 Prime Distance
    灯 & 树
    [HNOI2013]游走
    A
    B
    hdu 1247 Hat’s Words(字典树)
  • 原文地址:https://www.cnblogs.com/wayne173/p/3768200.html
Copyright © 2020-2023  润新知