unit RunOne;
interface
const
MI_QUERYWINDOWHANDLE = 1;
MI_RESPONDWINDOWHANDLE = 2;
MI_ERROR_NONE = 0;
MI_ERROR_FAILSUBCLASS = 1;
MI_ERROR_CREATINGMUTEX = 2;
// Call this function to determine if error occurred in startup.
// Value will be one or more of the MI_ERROR_* error flags.
function GetMIError: Integer;
implementation
uses Forms, Windows, SysUtils;
const
UniqueAppStr = 'NewCQ';
var
MessageId: Integer;
WProc: TFNWndProc;
MutHandle: THandle;
MIError: Integer;
function GetMIError: Integer;
begin
Result := MIError;
end;
function NewWndProc(Handle: HWND; Msg: Integer; wParam, lParam: Longint):
Longint; stdcall;
begin
Result := 0;
// If this is the registered message...
if Msg = MessageID then
begin
case wParam of
MI_QUERYWINDOWHANDLE:
// A new instance is asking for main window handle in order
// to focus the main window, so normalize app and send back
// message with main window handle.
begin
if IsIconic(Application.Handle) then
begin
Application.MainForm.WindowState := wsNormal;
Application.Restore;
end;
PostMessage(HWND(lParam), MessageID, MI_RESPONDWINDOWHANDLE,
Application.MainForm.Handle);
end;
MI_RESPONDWINDOWHANDLE:
// The running instance has returned its main window handle,
// so we need to focus it and go away.
begin
SetForegroundWindow(HWND(lParam));
Application.Terminate;
end;
end;
end
// Otherwise, pass message on to old window proc
else
Result := CallWindowProc(WProc, Handle, Msg, wParam, lParam);
end;
procedure SubClassApplication;
begin
// We subclass Application window procedure so that
// Application.OnMessage remains available for user.
WProc := TFNWndProc(SetWindowLong(Application.Handle, GWL_WNDPROC,
Longint(@NewWndProc)));
// Set appropriate error flag if error condition occurred
if WProc = nil then
MIError := MIError or MI_ERROR_FAILSUBCLASS;
end;
procedure DoFirstInstance;
// This is called only for the first instance of the application
begin
// Create the mutex with the (hopefully) unique string
MutHandle := CreateMutex(nil, False, UniqueAppStr);
if MutHandle = 0 then
MIError := MIError or MI_ERROR_CREATINGMUTEX;
end;
procedure BroadcastFocusMessage;
// This is called when there is already an instance running.
var
BSMRecipients: DWORD;
begin
// Prevent main form from flashing
Application.ShowMainForm := False;
// Post message to try to establish a dialogue with previous instance
BSMRecipients := BSM_APPLICATIONS;
BroadCastSystemMessage(BSF_IGNORECURRENTTASK or BSF_POSTMESSAGE,
@BSMRecipients, MessageID, MI_QUERYWINDOWHANDLE,
Application.Handle);
end;
procedure InitInstance;
begin
SubClassApplication; // hook application message loop
MutHandle := OpenMutex(MUTEX_ALL_ACCESS, False, UniqueAppStr);
if MutHandle = 0 then
// Mutex object has not yet been created, meaning that no previous
// instance has been created.
DoFirstInstance
else
BroadcastFocusMessage;
end;
initialization
MessageID := RegisterWindowMessage(UniqueAppStr);
InitInstance;
finalization
// Restore old application window procedure
if WProc <> nil then
SetWindowLong(Application.Handle, GWL_WNDPROC, LongInt(WProc));
if MutHandle <> 0 then CloseHandle(MutHandle); // Free mutex
end.