• VVC: Internal Error cad


    Found this a problem with Acad 2015 - if you get this error go into your code and look for 'mapcar' then within that look for 'command' and change to 'command-s'

    (if plst
      (progn
       (mapcar
       '(lambda (X)
         ;turn layer on
         (if (> (cadr X) 0)
    (command-s "._-LAYER" "_ON" (car X) "")
         );i
        );l
         plst
       );m
      );p

    Hope this helps some people as it was hard to find
     
     
     

    command-s (AutoLISP)

     
     
     
     

    Executes an AutoCAD command and the supplied input

    Supported Platforms: Windows and Mac OS             

                   

    Signature               

    (command-s [cmdname [arguments ...]])
    cmdname
                            

    Type: String                         

    Name of the command to execute.                         

    arguments
                            

    Type: Integer, Real, String, or List                         

    The command input to supply to the command being executed.                         

    The arguments to the command function can be strings, reals, integers, or points, as expected by the prompt sequence of the                           executed command. A null string ("") is equivalent to pressing Enter on the keyboard.                         

                   

    Return Values               

    Type: Nil                

    nil is returned by the function when the command is done executing on the provided arguments. An *error* is returned when the function fails to complete successfully.                

                   

    Remarks               

    See the sections later in this topic for more information.                

                   

    Examples               

    The following example demonstrates how to execute the AutoCAD CIRCLE command and create a circle with a diameter of 2.75.                                 

    Command: (command-s "_circle" "5,4" "_d" 2.75)
    nil

    The following example demonstrates how to prompt the user for the center point of the circle.                

    Command: (setq cPt (getpoint "
    Specify center point: "))
    (5.0 4.0 0.0)
    
    Command: (command-s "_.circle" cPt "_d" 2.75)
    nil

    The following is an invalid use of prompting for user input with the command-s function.                

    Command: (command-s "_.circle" (getpoint "
    Specify center point: ") "_d" 2.75)
                   

    Differences from the Command Function               

    The command-s function is a variation of the command function which has some restrictions on command token content, but is both faster than command and can be used in *error* handlers due to internal logic differences.                

    A command token is a single argument provided to the command-s function. This could be a string, real, integer, point, entity name, list, and so on. The following example shows the AutoCAD                  LINE command and three command tokens:                

    (command-s "_line" "0,0" "5,7" "")

    The "-s" suffix stands for "subroutine" execution of the supplied command tokens. In this form, AutoCAD is directly called                  from AutoLISP, processes the supplied command tokens in a temporary command processor distinct from the main document command                  processor, and then returns, thus terminating the temporary command processor. The command that is being executed must be                  started and completed in the same command-s function.                

    In contrast, the command function remains a "co-routine" execution of the supplied command tokens, where AutoLISP evaluates the tokens one at a time,                  sending the result to AutoCAD, and then returning to allow AutoCAD to process that token. AutoCAD then calls AutoLISP back,                  and AutoLISP resumes evaluation of the expression in progress. In this logic flow, subsequent token expressions can query                  AutoCAD for the results of previous token processing and use it.                

    In summary, the "co-routine" style of command token processing is more functionally powerful, but is limited in when it can                  be used when running. The "subroutine" style of command token processing can be used in a much wider range of contexts, but                  processes all command tokens in advance, and actual execution is non-interactive. For the same set of command tokens, command-s function is significantly faster.                

                   

    Known Considerations               

    When using the command-s function, you must take the following into consideration:                

                        
    • Token streams fed in a single command-s expression must represent a full command and its input. Any commands in progress when                     command tokens are all processed will be cancelled. The following is not valid with the command-s function:                      
      (command-s "_line")
      (command-s "2,2" "12.25,9" "")
    • All command tokens will be evaluated before they are handed over to AutoCAD for execution. In contrast, the command function actually performs each command token evaluation and then feeds the result to AutoCAD, which processes it before                     the next command token is processed.                   
    • No "Pause" command tokens may be used. Expressions that interact with the drawing area or Command Window may be used, but                     will all be processed before AutoCAD receives and processes any of them.                      

      The following is not valid with the command-s function:                      

      (command-s "_line" "0,0" PAUSE "")
    ImportantAlthough the command-s function is similar to the command function, caution should be taken when using U or UNDO to roll back the system state if there is an AutoCAD command already                     in progress when the AutoLISP expression is entered. In that case, the results of running UNDO may cause the command in progress                     to fail or even crash AutoCAD.                   
                   

    *error* Handler               

    If your *error* handler uses the command function, consider updating the way you define your custom *error* handlers using the following methods:                

                        
    • Substitute command-s for command in *error* handler                     

      For typical *error* handler cases where the previous state of the program needs to be restored and a few batch commands are executed, you can                        substitute (command-s <...>) for (command <...>). The *error* handler is called from the same context as it always has been.                      

      The following demonstrates a based *error* handler using the command-s function:                      

      (defun my_err(s)
        (prompt "
      ERROR: mycmd failed or was cancelled")
        (setvar "clayer" old_clayer)
        (command-s "_.UNDO" "_E")
        (setq *error* mv_oer)
      )
      
      (defun c:mycmd ()
        (setq old_err *error*
              *error* my_err
              old_clayer (getvar "clayer")
        )
      
        (setq insPt (getpoint "
      Specify text insertion: "))
      
        (if (/= insPt nil)
          (progn
            (command-s "_.UNDO" "_BE")
            (command-s "-_LAYER" "_M" "Text" "_C" "3" "" "")
            (command-s "_-TEXT" insPt "" "0" "Sample Text")
            (command-s "_.UNDO" "_E")
          )
        )
      
        (setvar "clayer" old_clayer)
        (setq *error* mv_oer)
       (princ)
      )
    • Retaining the use of the command function in *error* handler                     

      If using the command-s function is not viable option, then the command function can still be used, but only at the expense of losing access to any local symbols that would normally be on the AutoLISP                        call stack at the time of the *error* processing.                      

      The following is an overview of what is required to continue to use the command function in the *error* handler.                      

                                
      • When overriding the *error* symbol with a custom *error* handler, invoke the *push-error-using-command* function to inform AutoLISP that error handling will be used with the proceeding command functions.                            
        NoteWhenever an AutoLISP expression evaluation begins, the AutoLISP engine assumes that the command function will not be allowed within an *error* handler.                               
      • If the *error* handler refers to local symbols that are on the AutoLISP stack at the point where AutoLISP program failed or was cancelled,                           you must remove those references, or make the referenced symbols global symbols.                            

        All local symbols on the AutoLISP call stack are pushed out of scope because the AutoLISP evaluator is reset before entering                              the *error* handler.                            

      Now the command function can be used within the *error* handler.                      

      However, if your program actually pushes and pops error handlers as part of its operations, or your AutoLISP logic can be                        invoked while other unknown AutoLISP logic is invoked, there are a couple more steps you may have to make.                      

                                
      • When restoring an old error handler, also invoke the *pop-error-mode* function to reverse the effects of any call to the *push-error-using-command* or *push-error-using-stack* functions.                         
      • If your logic has nested pushes and pops of the *error* handler, and an *error* handler has been set up to use the command function by invoking *push-error-using-command*, while the nested handler will not use it, you can provide access to the locally defined symbols on the AutoLISP stack by                           invoking *push-error-using-stack* at the same point where you set *error* to the current handler. If this is done, you must also invoke *pop-error-mode* after the old *error* handler is restored.