• 7 Scatter-loading Features


    7.1 About scatter-loading

    The scatter-loading mechanism enables you to specify the memory map of an image to the linker using a description in a text file.

    Scatter-loading gives you complete control over the grouping and placement of image components. You can use scatter-loading to create simple images, but it is generally only used for images that have a complex memory map. That is, where multiple memory regions are scattered in the memory map at load and execution time.
    An image memory map is made up of regions and output sections. Every region in the memory map can have a different load and execution address.
    To construct the memory map of an image, the linker must have:
    • Grouping information that describes how input sections are grouped into output sections and regions.
    • Placement information that describes the addresses where regions are to be located in the memory maps.
    When the linker creates an image using a scatter file, it creates some region-related symbols. The linker creates these special symbols only if your code references them.
     

    7.2 When to use scatter-loading

    Scatter-loading is usually required for implementing embedded systems because these use ROM, RAM, and memory-mapped peripherals.

    Situations where scatter-loading is either required or very useful:
    Complex memory maps
    Code and data that must be placed into many distinct areas of memory require detailed instructions on where to place the sections in the memory space.
    Different types of memory
    Many systems contain a variety of physical memory devices such as flash, ROM, SDRAM, and fast SRAM. A scatter-loading description can match the code and data with the most appropriate type of memory. For example, interrupt code might be placed into fast SRAM to improve interrupt response time but infrequently-used configuration information might be placed into slower flash memory.
    Memory-mapped peripherals
    The scatter-loading description can place a data section at a precise address in the memory map so that memory mapped peripherals can be accessed.
    Functions at a constant location
    A function can be placed at the same location in memory even though the surrounding application has been modified and recompiled. This is useful for jump table implementation.
    Using symbols to identify the heap and stack
    Symbols can be defined for the heap and stack location when the application is linked. 

    7.4 Scatter-loading images with a simple memory map

    For images with a simple memory map, you can specify the memory map using only linker command-line options, or with a scatter file.

    If an image has a simple memory map, you can either:
    • Use a scatter file.
    • Specify the memory map using only linker command-line options.
    The following figure shows a simple memory map:
    Figure 7-1 Simple scatter-loaded memory map
    The following example shows the corresponding scatter-loading description that loads the segments from the object file into memory:
    LOAD_ROM 0x0000 0x8000       ; Name of load region (LOAD_ROM),
                                 ; Start address for load region (0x0000),
                                 ; Maximum size of load region (0x8000)
    {
         0x0000 0x8000   ; Name of first exec region (EXEC_ROM),
                                 ; Start address for exec region (0x0000),
                                 ; Maximum size of first exec region (0x8000)
        {
            * (+RO)              ; Place all code and RO data into
                                 ; this exec region
        }
        SRAM 0x10000 0x6000      ; Name of second exec region (SRAM),
                                 ; Start address of second exec region (0x10000),
                                 ; Maximum size of second exec region (0x6000)
        {
            * (+RW, +ZI)         ; Place all RW and ZI data into
                                 ; this exec region
        }
    }
    The maximum size specifications for the regions are optional. However, if you include them, they enable the linker to check that a region does not overflow its boundary.
    Apart from the limit checking, you can achieve the same result with the following linker command-line:
    armlink --ro_base 0x0 --rw_base 0x10000
     
     

    7.5 Scatter-loading images with a complex memory map

    For images with a complex memory map, you cannot specify the memory map using only linker command-line options. Such images require the use of a scatter file.

    The following figure shows a complex memory map:
    Figure 7-2 Complex memory map

    The following example shows the corresponding scatter-loading description that loads the segments from the program1.o and program2.o files into memory:
    LOAD_ROM_1 0x0000              ; Start address for first load region (0x0000)
    {
        EXEC_ROM_1 0x0000          ; Start address for first exec region (0x0000)
        {
            program1.o (+RO)       ; Place all code and RO data from
                                   ; program1.o into this exec region
        }
        DRAM 0x18000 0x8000        ; Start address for this exec region (0x18000),
                                   ; Maximum size of this exec region (0x8000)
        {
            program1.o (+RW, +ZI)  ; Place all RW and ZI data from
                                   ; program1.o into this exec region
        }
    }
    LOAD_ROM_2 0x4000              ; Start address for second load region (0x4000)
    {
        EXEC_ROM_2 0x4000
        {
            program2.o (+RO)       ; Place all code and RO data from
                                   ; program2.o into this exec region
        }
        SRAM 0x8000 0x8000
        {
            program2.o (+RW, +ZI)  ; Place all RW and ZI data from
                                   ; program2.o into this exec region
        }
    }

    Caution

    The scatter-loading description in this example specifies the location for code and data for program1.o and program2.o only. If you link an additional module, for example, program3.o, and use this description file, the location of the code and data for program3.o is not specified.
    Unless you want to be very rigorous in the placement of code and data, it is advisable to use the * or .ANY specifier to place leftover code and data.
     
     

    7.6 Scatter file with link to bit-band objects

    In devices with the ARMv7-M architecture, the SRAM and Peripheral regions each have a bit-band feature.

    You can access each bit in the bit-band region individually at a different address, called the bit-band alias. For example, to access bit[13] of the word at 0x20000001, you can use the address 0x22000054.
    The following table shows the bit-band regions and aliases within the SRAM and Peripheral memory regions.

    Table 7-1 ARMv7-M bit-band regions and aliases

    Memory region
    Description
    Address range
    SRAM
    Bit-band region
    0x20000000-0x200FFFFF
     
    Bit-band alias
    0x22000000-0x23FFFFFF
    Peripheral
    Bit-band region
    0x40000000-0x400FFFFF
     
    Bit-band alias
    0x42000000-0x43FFFFFF
    The following is an example scatter file that links bit-band objects.
    FLASH_LOAD 0x20000000
    {
        RW 0x20000000  ; RW data at the start of bit band region
      {
        * (+RW-DATA)
      }
      RO +0 FIXED        ; Followed by the RO Data
      {
         * (+RO-DATA)
      }
      CODEDATA +0   ; Followed by everything else
      { 
        * (+RO-CODE)
        * (+ZI)             ; ZI follows straight after
      }
      ARM_LIB_HEAP  +0 EMPTY 0x10000  ; heap starts after that
      {
      }
      ARM_LIB_STACK 0x20100000 EMPTY -0x10000    ; stack starts at the 
                                                 ; top of bit band region
      {
      }
    }
     

    7.12 Methods of placing functions and data at specific addresses

    There are various methods available to place functions and data at specific addresses.

    Where they are required, the compiler normally produces RO, RW, ZI, and XO sections from a single source file. These sections contain all the code and data from the source file. To place a single function or data item at a fixed address, you must enable the linker to process the function or data separately from the rest of the input files.
    The linker has two methods that enable you to place a section at a specific address:
    • You can create a scatter file that defines an execution region at the required address with a section description that selects only one section.
    • For a specially-named section the linker can get the placement address from the section name. These specially-named sections are called __at sections.
    To place a function or variable at a specific address it must be placed in its own section. There are several ways to do this:
    • Place the function or data item in its own source file.
    • Use __attribute__((at(address))) to place variables in a separate section at a specific address.
    • Use __attribute__((section("name"))) to place functions and variables in a named section.
    • Use the AREA directive from assembly language. In assembly code, the smallest locatable unit is an AREA.
    • Use the --split_sections compiler option to generate one ELF section for each function in the source file.
      This option results in a small increase in code size for some functions because it reduces the potential for sharing addresses, data, and string literals between functions. However, this can help to reduce the final image size overall by enabling the linker to remove unused functions when you specify armlink --remove.

    Example of how to place a variable at a specific address without scatter-loading

    To place code and data at specific addresses without a scatter file:
    1. Create the source file main.c containing the following code:
      #include <stdio.h>
      extern int sqr(int n1);
      int gSquared __attribute__((at(0x5000)));  // Place at 0x5000
      int main()
      {
          gSquared=sqr(3);
          printf("Value squared is: %d
      ", gSquared);
      }
    2. Create the source file function.c containing the following code:
      int sqr(int n1)
      {
          return n1*n1;
      }
    3. Compile and link the sources:
      armcc -c -g function.c
      armcc -c -g main.c
      armlink --map function.o main.o -o squared.axf
      The --map option displays the memory map of the image. Also, --autoat is the default.
    In this example, __attribute__((at(0x5000))) specifies that the global variable gSquared is to be placed at the absolute address 0x5000. gSquared is placed in the execution region ER$$.ARM.__at_0x00005000 and load region LR$$.ARM.__at_0x00005000.

    Note

    Although the address is specified as 0x5000 in the source file, the region names and section name addresses are normalized to eight hexadecimal digits.
    The memory map shows:
    …
      Load Region LR$$.ARM.__at_0x00005000 (Base: 0x00005000, Size: 0x00000000, Max: 0x00000004, ABSOLUTE)
    
        Execution Region ER$$.ARM.__at_0x00005000 (Base: 0x00005000, Size: 0x00000004, Max: 0x00000004, ABSOLUTE, UNINIT)
    
        Base Addr    Size         Type   Attr      Idx    E Section Name        Object
    
        0x00005000   0x00000004   Zero   RW           13    .ARM.__at_0x00005000  main.o

    Example of how to place a variable in a named section with scatter-loading

    To modify your source code to place code and data in a specific section using a scatter file:
    1. Create the source file main.c containing the following code:
      #include <stdio.h>
      extern int sqr(int n1);
      int gSquared __attribute__((section("foo")));  // Place in section foo
      int main()
      {
          gSquared=sqr(3);
          printf("Value squared is: %d
      ", gSquared);
      }
    2. Create the source file function.c containing the following code:
      int sqr(int n1)
      {
          return n1*n1;
      }
    3. Create the scatter file scatter.scat containing the following load region:
      LR1 0x0000 0x20000
      {
          ER1 0x0 0x2000
          {
              *(+RO)                ; rest of code and read-only data
          }
          ER2 0x8000 0x2000
          {
              main.o
          }
          ER3 0x10000 0x2000
          {
              function.o
              *(foo)                ; Place gSquared in ER3
          }
          ; RW and ZI data to be placed at 0x200000
          RAM 0x200000 (0x1FF00-0x2000)
          {
              *(+RW, +ZI)
          }
          ARM_LIB_STACK 0x800000 EMPTY -0x10000
          {
          }
          ARM_LIB_HEAP  +0 EMPTY 0x10000
          {
          }
      }
      The ARM_LIB_STACK and ARM_LIB_HEAP regions are required because the program is being linked with the semihosting libraries.
    4. Compile and link the sources:
      armcc -c -g function.c
      armcc -c -g main.c
      armlink --map --scatter=scatter.scat function.o main.o -o squared.axf
      The --map option displays the memory map of the image. Also, --autoat is the default.
    In this example, __attribute__((section("foo"))) specifies that the global variable gSquared is to be placed in a section called foo. The scatter file specifies that the section foo is to be placed in the ER3 execution region.
    The memory map shows:
      Load Region LR1 (Base: 0x00000000, Size: 0x00001570, Max: 0x00020000, ABSOLUTE)
    …
        Execution Region ER3 (Base: 0x00010000, Size: 0x00000010, Max: 0x00002000, ABSOLUTE)
    
        Base Addr    Size         Type   Attr      Idx    E Section Name        Object
    
        0x00010000   0x0000000c   Code   RO            3    .text               function.o
        0x0001000c   0x00000004   Data   RW           15    foo                 main.o
    …

    Note

    If you omit *(foo) from the scatter file, the section is placed in the region of the same type. That is RAM in this example.

    Example of how to place a variable at a specific address with scatter-loading

    To modify your source code to place code and data at a specific address using a scatter file:
    1. Create the source file main.c containing the following code:
      #include <stdio.h>
      extern int sqr(int n1);
      // Place at address 0x10000
      const int gValue __attribute__((section(".ARM.__at_0x10000"))) = 3;
      int main()
      {
          int squared;
          squared=sqr(gValue);
          printf("Value squared is: %d
      ", squared);
      }
    2. Create the source file function.c containing the following code:
      int sqr(int n1)
      {
          return n1*n1;
      }
    3. Create the scatter file scatter.scat containing the following load region:
      LR1 0x0
      {
          ER1 0x0
          {
              *(+RO)                      ; rest of code and read-only data
          }
          ER2 +0
          {
              function.o
              *(.ARM.__at_0x10000)        ; Place gValue at 0x10000
          }
          ; RW and ZI data to be placed at 0x200000
          RAM 0x200000 (0x1FF00-0x2000)
          {
              *(+RW, +ZI)
          }
          ARM_LIB_STACK 0x800000 EMPTY -0x10000
          {
          }
          ARM_LIB_HEAP  +0 EMPTY 0x10000
          {
          }
      }
      The ARM_LIB_STACK and ARM_LIB_HEAP regions are required because the program is being linked with the semihosting libraries.
    4. Compile and link the sources:
      armcc -c -g function.c
      armcc -c -g main.c
      armlink --no_autoat --scatter=scatter.scat --map function.o main.o -o squared.axf
      The --map option displays the memory map of the image.
    The memory map shows that the variable is placed in the ER2 execution region at address 0x10000:
    …
        Execution Region ER2 (Base: 0x00001578, Size: 0x0000ea8c, Max: 0xffffffff, ABSOLUTE)
    
        Base Addr    Size         Type   Attr      Idx    E Section Name        Object
    
        0x00001578   0x0000000c   Code   RO            3    .text               function.o
        0x00001584   0x0000ea7c   PAD
        0x00010000   0x00000004   Data   RO           15    .ARM.__at_0x10000   main.o
    …
    In this example, the size of ER1 is uknown. Therefore, gValue might be placed in ER1 or ER2. To make sure that gValue is placed in ER2, you must include the corresponding selector in ER2 and link with the --no_autoat command-line option. If you omit --no_autoat, gValue is to placed in a separate load region LR$$.ARM.__at_0x10000 that contains the execution region ER$$.ARM.__at_0x.ARM.__at_0x10000.
     
     

    7.15 Examples of using placement algorithms for .ANY sections

    These examples show the operation of the placement algorithms for RO-CODE sections in sections.o.

    The input section properties and ordering are shown in the following table:

    Table 7-2 Input section properties for placement of .ANY sections

    NameSize
    sec1 0x4
    sec2 0x4
    sec3 0x4
    sec4 0x4
    sec5 0x4
    sec6 0x4
    The scatter file used for the examples is:
    LR 0x100
    {
      ER_1 0x100 0x10
      {
         .ANY
      }
      ER_2 0x200 0x10
      {
         .ANY
      }
    }

    Note

    These examples have --any_contingency disabled.

    Example for first_fit, next_fit, and best_fit

    This example shows the situation where several sections of equal size are assigned to two regions with one selector. The selectors are equally specific, equivalent to .ANY(+R0) and have no priority.
        Execution Region ER_1 (Base: 0x00000100, Size: 0x00000010, Max: 0x00000010, ABSOLUTE)
        Base Addr    Size         Type   Attr      Idx    E Section Name        Object
        0x00000100   0x00000004   Code   RO            1    sec1                sections.o
        0x00000104   0x00000004   Code   RO            2    sec2                sections.o
        0x00000108   0x00000004   Code   RO            3    sec3                sections.o
        0x0000010c   0x00000004   Code   RO            4    sec4                sections.o
        Execution Region ER_2 (Base: 0x00000200, Size: 0x00000008, Max: 0x00000010, ABSOLUTE)
        Base Addr    Size         Type   Attr      Idx    E Section Name        Object
        0x00000200   0x00000004   Code   RO            5    sec5                sections.o
        0x00000204   0x00000004   Code   RO            6    sec6                sections.o
    In this example:
    • For first_fit the linker first assigns all the sections it can to ER_1, then moves on to ER_2 because that is the next available region.
    • For next_fit the linker does the same as first_fit. However, when ER_1 is full it is marked as FULL and is not considered again. In this example, ER_1 is completely full. ER_2 is then considered.
    • For best_fit the linker assigns sec1 to ER_1. It then has two regions of equal priority and specificity, but ER_1 has less space remaining. Therefore, the linker assigns sec2 to ER_1, and continues assigning sections until ER_1 is full.

    Example for worst_fit

    This example shows the image memory map when using the worst_fit algorithm.
        Execution Region ER_1 (Base: 0x00000100, Size: 0x0000000c, Max: 0x00000010, ABSOLUTE)
        Base Addr    Size         Type   Attr      Idx    E Section Name        Object
        0x00000100   0x00000004   Code   RO            1    sec1                sections.o
        0x00000104   0x00000004   Code   RO            3    sec3                sections.o
        0x00000108   0x00000004   Code   RO            5    sec5                sections.o
        Execution Region ER_2 (Base: 0x00000200, Size: 0x0000000c, Max: 0x00000010, ABSOLUTE)
        Base Addr    Size         Type   Attr      Idx    E Section Name        Object
        0x00000200   0x00000004   Code   RO            2    sec2                sections.o
        0x00000204   0x00000004   Code   RO            4    sec4                sections.o
        0x00000208   0x00000004   Code   RO            6    sec6                sections.o
    The linker first assigns sec1 to ER_1. It then has two equally specific and priority regions. It assigns sec2 to the one with the most free space, ER_2 in this example. The regions now have the same amount of space remaining, so the linker assigns sec3 to the first one that appears in the scatter file, that is ER_1.

    Note

    The behavior of worst_fit is the default behavior in this version of the linker, and it is the only algorithm available and earlier linker versions.
     
     

    7.16 Example of next_fit algorithm showing behavior of full regions, selectors, and priority

    This example shows the operation of the next_fit placement algorithm for RO-CODE sections in sections.o.

    The input section properties and ordering are shown in the following table:

    Table 7-3 Input section properties for placement of sections with next_fit

    NameSize
    sec1 0x14
    sec2 0x14
    sec3 0x10
    sec4 0x4
    sec5 0x4
    sec6 0x4
    The scatter file used for the examples is:
    LR 0x100
    {
      ER_1 0x100 0x20
      {
         .ANY1(+RO-CODE)
      }
      ER_2 0x200 0x20
      {
         .ANY2(+RO)
      }
      ER_3 0x300 0x20
      {
         .ANY3(+RO)
      }
    }

    Note

    This example has --any_contingency disabled.
    The next_fit algorithm is different to the others in that it never revisits a region that is considered to be full. This example also shows the interaction between priority and specificity of selectors - this is the same for all the algorithms.
        Execution Region ER_1 (Base: 0x00000100, Size: 0x00000014, Max: 0x00000020, ABSOLUTE)
        Base Addr    Size         Type   Attr      Idx    E Section Name        Object
        0x00000100   0x00000014   Code   RO            1    sec1                sections.o
        Execution Region ER_2 (Base: 0x00000200, Size: 0x0000001c, Max: 0x00000020, ABSOLUTE)
        Base Addr    Size         Type   Attr      Idx    E Section Name        Object
        0x00000200   0x00000010   Code   RO            3    sec3                sections.o
        0x00000210   0x00000004   Code   RO            4    sec4                sections.o
        0x00000214   0x00000004   Code   RO            5    sec5                sections.o
        0x00000218   0x00000004   Code   RO            6    sec6                sections.o
        Execution Region ER_3 (Base: 0x00000300, Size: 0x00000014, Max: 0x00000020, ABSOLUTE)
        Base Addr    Size         Type   Attr      Idx    E Section Name        Object
        0x00000300   0x00000014   Code   RO            2    sec2                sections.o
    In this example:
    • The linker places sec1 in ER_1 because ER_1 has the most specific selector. ER_1 now has 0x6 bytes remaining.
    • The linker then tries to place sec2 in ER_1, because it has the most specific selector, but there is not enough space. Therefore, ER_1 is marked as full and is not considered in subsequent placement steps. The linker chooses ER_3 for sec2 because it has higher priority than ER_2.
    • The linker then tries to place sec3 in ER_3. It does not fit, so ER_3 is marked as full and the linker places sec3 in ER_2.
    • The linker now processes sec4. This is 0x4 bytes so it can fit in either ER_1 or ER_3. Because both of these sections have previously been marked as full, they are not considered. The linker places all remaining sections in ER_2.
    • If another section sec7 of size 0x8 exists, and is processed after sec6 the example fails to link. The algorithm does not attempt to place the section in ER_1 or ER_3 because they have previously been marked as full.
     
     

    7.19 Placement of code and data with __attribute__((section("name")))

    You can place code and data by separating them into their own objects without having to use toolchain-specific pragmas or attributes.

    However, you can also use __attribute__((section("name"))) to place an item in a separate ELF section. You can then use a scatter file to place the named sections at specific locations.

    Examples

    To use __attribute__((section("name"))) to place a variable in a separate section:
    1. Use __attribute__((section("name"))) to specify the named section where the variable is to be placed, for example:
      Naming a section
      int variable __attribute__((section("foo"))) = 10;
    2. Use a scatter file to place the named section, for example:
      Placing a section
      FLASH 0x24000000 0x4000000
      {
          …                                ; rest of code
          ADDER 0x08000000
          {
              file.o (foo)                  ; select section foo from file.o
          }
      }
    The following example shows the memory map for the FLASH load region:
    …
      Load Region FLASH (Base: 0x24000000, Size: 0x00000004, Max: 0x04000000, ABSOLUTE)
        Execution Region ADDER (Base: 0x08000000, Size: 0x00000004, Max: 0xffffffff, ABSOLUTE)
        Base Addr    Size         Type   Attr      Idx    E Section Name        Object
        0x08000000   0x00000004   Data   RW           16    foo                 file.o
    …
    Be aware of the following:
    • Linking with --autoat or --no_autoat does not affect the placement.
    • If scatter-loading is not used, the section is placed in the default ER_RW execution region of the LR_1 load region.
    • If you have a scatter file that does not include the foo selector, then the section is placed in the defined RW execution region.
    You can also place a function at a specific address using .ARM.__at_address as the section name. For example, to place the function sqr at 0x20000, specify:
    int sqr(int n1) __attribute__((section(".ARM.__at_0x20000")));
    int sqr(int n1)
    {
        return n1*n1;
    }
     
     
     
     
     
     
     
     