• CDC之Synchronizers


    1  Scenarios

     Two scenarios for passing signals across CDC boundaries:

      1) sometimes it's not necessary to sample every value, but be sure that the sampled values are accurate. One example is the set of gray

    code counters used in asynchronous FIFO. In asynchronous FIFO, synchronized gray code counters do not need to capture every legal value from

    the opposite clock domain, but it's critical that sampled values be accurate to recognize when full and empty conditions have occurred.

      2) a CDC signal must be properly recognized or recognized & acknowledged before a change occurs.

       In both of these scenarios, the CDC signals will require some form of synchronization into the receiving clock domain.

    2  Receiving clock domain

      1)  Two flip-flop synchronizer

         For most synchronization applications, the two flip-flop synchronizer is sufficient to remove all likely metastability.

          

      2)  Three flip-flop synchronizer

            For some very high speed designs, a third flop is added to increase the MTBF to a satisfactory duration of time.

        

    3  Sending clock domain

       Registering signals in the sending clock domain should generally be required.

        

    4  Example (Verilog)  

     1 module  sync_cell (
     2 
     3 // OUTPUTs
     4     data_out,                      // Synchronized data output
     5 
     6 // INPUTs
     7     clk,                           // Receiving clock
     8     data_in,                       // Asynchronous data input
     9     rst                            // Receiving reset (active high)
    10 );
    11 
    12 // OUTPUTs
    13 output              data_out;      // Synchronized data output
    14 
    15 // INPUTs
    16 input               clk;          // Receiving clock
    17 input               data_in;      // Asynchronous data input
    18 input               rst;          // Receiving reset (active high)
    19 
    20 
    21 //=================================================
    22 // 1)  SYNCHRONIZER
    23 //=================================================
    24 
    25 reg  [1:0] data_sync;
    26 
    27 always @(posedge clk or posedge rst)
    28   if (rst) data_sync <=  2'b00;
    29   else     data_sync <=  {data_sync[0], data_in};
    30 
    31 assign     data_out   =   data_sync[1];
    32 
    33 
    34 endmodule // sync_cell
  • 相关阅读:
    BNUOJ-26474 Bread Sorting 逆序对
    POJ-2480 Longge's problem 积性函数
    Bzoj-2705 Longge的问题 欧拉函数
    Bzoj-2820 YY的GCD Mobius反演,分块
    HDU-4689 Derangement DP
    [转]初学者程序语言的选择
    HDU-4705 Y 树形DP
    HDU-4704 Sum 大数幂取模
    HDU-4699 Editor 数据结构维护
    HDU-4696 Answers 纯YY
  • 原文地址:https://www.cnblogs.com/mengdie/p/4488880.html
Copyright © 2020-2023  润新知