• HP Proliant DL580 gen9 阵列卡P440AR 高速缓存 被禁用


    摘录内容:

    IMPORTANT: This issue does NOT occur when the operating system shuts down gracefully. In addition, an occurrence of the issue is extremely rare if the server experiences a sudden loss of power or a power outage.
    重要:当操作系统正常关闭时,这个问题不会发生。另外,如果服务器经历瞬间断电,该问题的发生是极少的。

    After the initial failure, the following IML event will be displayed after booting:
    初始化失败,重启后下列完整管理日志的事件将会显示
    Option ROM POST Error: - Write-Back Cache Restore Previously Failed. Caching is disabled. Action: Replace the Cache Module
    选项ROM的后置错误:以前的回写缓存恢复失败。缓存禁用。操作:替换缓存模块。
    Once this occurs, the controller will still function but the cache is disabled, causing a performance I/O issue on the Smart Array controller.
    一旦这个问题发生,控制器继续保持相应功能,但是缓存已禁用,在智能阵列控制器上引发一个I/O的问题。


    内容来源HPE官网文档:https://support.hpe.com/hpesc/public/docDisplay?docId=a00004045en_us

     

    例:一台HP的Proliant DL580 gen9的服务器,应用数据无法向磁盘正常读写

     

    HP工程师通过ILO管理工具,查看阵列卡Smart Array P440AR的控制器状态

      i.高速缓存状态:已永久禁用;
      ii.高速缓存状态详细信息:缓存已禁用,电源未连接;
      iii.警告:822 由于没有电池电容器连接到缓存模块,智能阵列P440AR位于嵌入式插槽的缓存已被禁用。

    故障现象:

    i.所有输入设备“刷卡机”显示连接失败或无响应;

    ii.服务器磁盘的I/O数据读写缓慢或有卡死现象;

    iii.通过同网段主机A,ping测刷卡机和服务器正常;

    iv.重启软件或者服务器,刷卡应用可短暂恢复。

    故障原因:

      HP工程师通过ILO管理工具查看阵列卡P440AR供电异常,打开服务器机盖检查发现,连接阵列卡的电容没供电。
      HP工程师说:“给阵列卡供电的电容大概4-5年的使用寿命”。

    解决办法:

      更换阵列卡P440AR的供电电容,观察一周,HP Proliant DL580 gen9的数据读写恢复正常。

    上述内容可能存在翻译或者描述问题,如有错误,请指正,谢谢!

    不要总羡慕别人的幸福,却常常忽略了自己生活中的美好!