• 解决T41 solaris11无法启动问题


    问题的故障是主机断电后,solaris11起不来了。在boot阶段报错:ERROR: boot-read fail

    以下是启动报错信息:

    SPARC T4-1, No Keyboard
    Copyright (c) 1998, 2012, Oracle and/or its affiliates. All rights reserved.
    OpenBoot 4.34.1, 32256 MB memory available, Serial #101718426.
    Ethernet address 0:10:e0:10:19:9a, Host ID: 8610199a.

    ERROR: boot-read fail
    Boot device: net  File and args:
    1000 Mbps full duplex Link up
    Requesting Internet Address for 0:10:e0:10:19:9a
    Requesting Internet Address for 0:10:e0:10:19:9a
    Requesting Internet Address for 0:10:e0:10:19:9a

    由于在OBP中boot-device设置的是disk net, 从磁盘引导失败后,就自动从net引导了。此系统根本没配置net引导,因此一直在试着从网络上获取IP地址信息。

    解决过程

    1. 在ILOM里设置OS不自动启动

    原系统在OBP里设置了auto-boot?=true,此处先在ILOM把自动启动去掉.

    串口登录ILOM,设置OS不自动启动

    set /HOST/bootmode script="setenv auto-boot? false"

    重启

    stop /SYS

    start /SYS

    切换到console

    start /SP/console

    启动后系统停止在ok状态

    2. 检查一下磁盘情况

    {0} ok probe-scsi-all
    /pci@400/pci@2/pci@0/pci@f/pci@0/usb@0,2/hub@2/hub@3/storage@2
      Unit 0   Removable Read Only device       AMI     Virtual CDROM   1.00

    /pci@400/pci@2/pci@0/pci@c/SUNW,qlc@0,1
    QLogic QLE2562  Host Adapter FCode(SPARC): 2.03  06/30/08
    Wait for link up - /
    Firmware version 4.03.02
    Adapter portID - 10200
    ************** Fabric Attached Devices **************
      Dev# 0 (0)   PortID 10000    Port WWN 200a00a0b848305a
       LUN    0(0)    DISK  SUN     CSM200_R        0760
       LUN    1(1)    DISK  SUN     CSM200_R        0760
       LUN    2(2)    DISK  SUN     CSM200_R        0760
       LUN    3(3)    DISK  SUN     CSM200_R        0760
       LUN    4(4)    DISK  SUN     CSM200_R        0760

      Dev# 1 (1)   PortID 10100    Port WWN 200b00a0b848305a
       LUN    0(0)    DISK  SUN     CSM200_R        0760
       LUN    1(1)    DISK  SUN     CSM200_R        0760
       LUN    2(2)    DISK  SUN     CSM200_R        0760
       LUN    3(3)    DISK  SUN     CSM200_R        0760
       LUN    4(4)    DISK  SUN     CSM200_R        0760


    /pci@400/pci@2/pci@0/pci@c/SUNW,qlc@0
    QLogic QLE2562  Host Adapter FCode(SPARC): 2.03  06/30/08
    Wait for link up - /
    Firmware version 4.03.02
    Adapter portID - 10200
    ************** Fabric Attached Devices **************
      Dev# 0 (0)   PortID 10000    Port WWN 200a00a0b8483059
       LUN    0(0)    DISK  SUN     CSM200_R        0760                           
       LUN    1(1)    DISK  SUN     CSM200_R        0760
       LUN    2(2)    DISK  SUN     CSM200_R        0760                           
       LUN    3(3)    DISK  SUN     CSM200_R        0760                           
       LUN    4(4)    DISK  SUN     CSM200_R        0760
      Dev# 1 (1)   PortID 10100    Port WWN 200b00a0b8483059
       LUN    0(0)    DISK  SUN     CSM200_R        0760                            
       LUN    1(1)    DISK  SUN     CSM200_R        0760                           
       LUN    2(2)    DISK  SUN     CSM200_R        0760                           
       LUN    3(3)    DISK  SUN     CSM200_R        0760                           
       LUN    4(4)    DISK  SUN     CSM200_R        0760
                                   
    /pci@400/pci@2/pci@0/pci@4/scsi@0

    FCode Version 1.00.61 , MPT Version 2.00, Firmware Version 9.00.00.00

    Target 9
      Unit 0   Removable Read Only device   TEAC     DV-W28SS-V       1.0B
      SATA device  PhyNum 6

    /pci@400/pci@1/pci@0/pci@4/scsi@0

    FCode Version 1.00.61 , MPT Version 2.00, Firmware Version 9.00.00.00

    Target 381 Volume 0
      Unit 0   Disk   LSI      Logical Volume   3000    583983104 Blocks, 298 GB
      VolumeDeviceName 3e90f849ae6f04a5  VolumeWWID 0e90f849ae6f04a5

    /pci@400/pci@1/pci@0/pci@0/SUNW,qlc@0,1
    QLogic QLE2562  Host Adapter FCode(SPARC): 2.03  06/30/08
    Wait for link up - /
    Firmware version 4.03.02
    Adapter portID - 10300
    ************** Fabric Attached Devices **************
      Dev# 0 (0)   PortID 10000    Port WWN 200a00a0b848305a
       LUN    0(0)    DISK  SUN     CSM200_R        0760
       LUN    1(1)    DISK  SUN     CSM200_R        0760
       LUN    2(2)    DISK  SUN     CSM200_R        0760
       LUN    3(3)    DISK  SUN     CSM200_R        0760
       LUN    4(4)    DISK  SUN     CSM200_R        0760
      Dev# 1 (1)   PortID 10100    Port WWN 200b00a0b848305a
       LUN    0(0)    DISK  SUN     CSM200_R        0760
       LUN    1(1)    DISK  SUN     CSM200_R        0760
       LUN    2(2)    DISK  SUN     CSM200_R        0760
       LUN    3(3)    DISK  SUN     CSM200_R        0760
       LUN    4(4)    DISK  SUN     CSM200_R        0760
                                   
    /pci@400/pci@1/pci@0/pci@0/SUNW,qlc@0
    QLogic QLE2562  Host Adapter FCode(SPARC): 2.03  06/30/08
    Wait for link up - /
    Firmware version 4.03.02
    Adapter portID - 10300
    ************** Fabric Attached Devices **************
      Dev# 0 (0)   PortID 10000    Port WWN 200a00a0b8483059
       LUN    0(0)    DISK  SUN     CSM200_R        0760
       LUN    1(1)    DISK  SUN     CSM200_R        0760
       LUN    2(2)    DISK  SUN     CSM200_R        0760
       LUN    3(3)    DISK  SUN     CSM200_R        0760
       LUN    4(4)    DISK  SUN     CSM200_R        0760
      Dev# 1 (1)   PortID 10100    Port WWN 200b00a0b8483059
       LUN    0(0)    DISK  SUN     CSM200_R        0760
       LUN    1(1)    DISK  SUN     CSM200_R        0760
       LUN    2(2)    DISK  SUN     CSM200_R        0760
       LUN    3(3)    DISK  SUN     CSM200_R        0760
       LUN    4(4)    DISK  SUN     CSM200_R        0760

    上述输出中显示为LUN的,都是来自存储的空间。红色部分是本地盘。此系统设置了硬RAID.

    3. 检查硬RAID信息

    {0} ok select /pci@400/pci@1/pci@0/pci@4/scsi@0
    {0} ok show-volumes
    Volume 0 Target 381  Type RAID1 (Mirroring)
      Name ids1vol  WWID 0e90f849ae6f04a5

      Optimal  Enabled  Volume Not Consistent
      2 Members                                         583983104 Blocks, 298 GB
      Disk 1
        Primary  Optimal
        Target 9      HITACHI  H106030SDSUN300G A2B0   PhyNum 0
      Disk 0
        Secondary  Optimal
        Target a      HITACHI  H106030SDSUN300G A2B0   PhyNum 1

    {0} ok unselect-dev

    4. 从指定路径启动OS

    从自动启动报错的信息来看(ERROR: boot-read fail) ,很可能是启动时没找到引导块。这并不一定表示磁盘坏了或者引导块坏了,也有可能是找的位置不对。一般情况下,主机掉电并不会造成磁盘出现损坏这么严重的问题。于是手工指定路径来启动OS.

    {0} ok boot /pci@400/pci@2/pci@0/pci@4/scsi@0/disk@w3e90f849ae6f04a5,0:a
    Boot device: /pci@400/pci@1/pci@0/pci@4/scsi@0/disk@w3e90f849ae6f04a5,0:a  File and args:
    SunOS Release 5.11 Version 11.0 64-bit
    Copyright (c) 1983, 2011, Oracle and/or its affiliates. All rights reserved.
    .....

    结果系统起来了。

    至于为什么是这个启动路径,我也不太清楚,完全是矇的。对于/pci@400/pci@1/pci@0/pci@4/scsi@0/disk@w3e90f849ae6f04a5,0:a 这个路径,大概情况如下:

    /pci@400/pci@1/pci@0/pci@4/scsi@0 这个好理解,表示磁盘的系统PCI中的位置

    /disk@  这个是固定的

    w3e90f849ae6f04a5 关键是这个值,此值相当于磁盘逻辑名称cXtYdZ中的"Y",此值可能与以下内容有关。

    Volume 0 Target 381 Type RAID1 (Mirroring)
    Name ids1vol WWID 0e90f849ae6f04a5

    其中w是固定的,3估计是 "Target 381” 中的"3”, e90f849ae6f04a5是 WWID的值去掉前面的"0". 至于为什么是这样,我也不知道。只时当时我上网查的时候,刚好看到有个人的系统盘也是做了硬RAID,OS中的系统盘名称与此类似。我仔细分析了他的系统盘名称,做出了以上猜测。

    ,0:a  这个也好理解,0表示d0,即磁盘0;a表示分区0

    5. 设置启动盘别名

    系统起来后,需要设置一下别名,避免下次重启还得手工指定路径。

    root@racnode1:~# eeprom "nvramrc=devalias bootdisk /pci@400/pci@1/pci@0/pci@4/scsi@0/disk@w3e90f849ae6f04a5,0:a"
    root@racnode1:~# eeprom boot-device="bootdisk"
    root@racnode1:~# eeprom "use-nvramrc?=true"

    备注:w3e90f849ae6f04a5这个值实际上是probe-scsi-all命令输出的VolumeDeviceName值前面加上"w"

    Target 381 Volume 0 
      Unit 0   Disk   LSI      Logical Volume   3000    583983104 Blocks, 298 GB 
      VolumeDeviceName 3e90f849ae6f04a5  VolumeWWID 0e90f849ae6f04a5