• 一种新型参考图谱有助于提高超声检查RA关节的可信度


    原文

    译文

    Ann Rheum Dis. 2011 Jul 22. [Epub ahead of print]

     

    Examination of intra and interrater reliability with a new ultrasonographic reference atlas for scoring of synovitis in patients with rheumatoid arthritis.

     

    Hammer HB, Bolton-King P, Bakkeheim V, Berg TH, Sundt E, Kongtorp AK, Haavardsholm EA.

     

    Source

    1Department of Rheumatology, Diakonhjemmet Hospital, Oslo, Norway.

     

    Abstract

     

    OBJECTIVE: Synovitis in patients with rheumatoid arthritis (RA) may be scored semiquantitatively (0-3) for B-mode (BM) and power Doppler (PD) ultrasonography. The objective was to assess the reliability of BM and PD examinations with a novel ultrasonographic atlas as reference.

    METHODS: Representative ultrasound images (including scores 0-3) of BM and PD from 24 different joints were collected to develop an ultrasonographic atlas. Ten RA patients were assessed twice by five rheumatologists performing BM and PD scoring (0-3) of 16 joints bilaterally (metacarpophalangeal 1-5, wrist (radiocarpal, intercarpal, radioulnar), elbow, knee, talocrural and metatarsophalangeal 1-5), with the novel ultrasonographic atlas as a reference.

    RESULTS: The median (range) percentages of exact agreements for BM/PD assessments were 73.1 (70.3-80.6)/83.7 (76.7-87.6) and for close agreement 98.1 (96.2-99.7)/98.0 (96.8-98.4) with weighted κ values of median (range) 0.77 (0.70-0.83) for BM and 0.83 (0.73-0.86) for PD. The intrarater intraclass correlation coefficients (ICC) for BM/PD scores were 0.95 (0.93-0.99)/0.97 (0.95-0.99) and interrater ICC were 0.95 (0.86-0.99)/0.97 (0.94-1.00). Scoring of 32 joints was completed in median 15 min (range 12-20).

    CONCLUSION: With the use of an ultrasonographic atlas as reference high intra and interrater reliability was found for BM and PD scoring. This novel atlas may be a useful resource in clinical practice and research.

     

    PMID: 21784724

     

    一种新型参考图谱有助于提高超声检查RA关节的可信度

     

    Hammer HB, et al. Ann Rheum Dis. 2011 Jul 22. 提前在线发表.

     

     

    目的: 类风湿关节炎(RA)患者的滑膜炎可以通过B(BM)和多普勒超声(PD)进行半定量评分(0 ~ 3)。本研究旨在以一种新版超声图谱为参照评估BMPD检查的可信度。

    方法: 收集有代表性的24个关节超声影像学资料(包括评分)并制备成标准图谱。以该图谱为参照,由5名风湿病医生操作BMPD分别两次检查10RA病人16个关节对(掌指关节1 ~ 5,腕关节(桡腕, 掌骨间, 尺桡),肘关节,膝关节,踝关节以及跖趾关节1 ~ 5)并评分(0 ~ 3)

    结果: 不同操作者对BM/PD评估的完全一致性中位数(范围)73.1 (70.3 ~ 80.6)83.7 (76.7 ~ 87.6),接近一致率为98.1 (96.2 ~ 99.7) 98.0 (96.8 ~ 98.4)BMPD中位数(范围)的加权κ值为0.77 (0.70 ~ 0.83)0.83 (0.73 ~ 0.86)BM/PD的同一判读者组内相关系数 (ICC)为分别为0.95 (0.93 ~ 0.99)0.97 (0.95 ~ 0.99)和判读者之间ICC分别为0.95 (0.86 ~ 0.99)0.97 (0.94 ~ 1.00)。完成32个关节评估的耗时中位数为15分钟(范围: 12 ~ 20分钟)

    结论: 以超声图谱为参照对BMPD评分时,操作者自身以及不同操作者之间的可信度是高的。这种新型图谱对临床实践和科研而言可能是一种有用的资源。

  • 相关阅读:
    defer与async的区别
    Promise 的含义
    SCSS 与 Sass 异同
    CSS总结2
    CSS总结1
    jQuery-插件,优化
    jQuery-表格以及表单
    jQuery-事件以及动画
    jQuery-ajax
    jQuery-DOM操作
  • 原文地址:https://www.cnblogs.com/T2T4RD/p/5464252.html
Copyright © 2020-2023  润新知