单机多实例mysql部署安装
- 目的需求
在单台虚拟机部署部署多实例mysql,用于配置mysql replication,MHA等。
- 思路
多实例安装mysql可以参考《源编译MySQL8.0的安装》文档。修改my.cnf的配置文件和目录文件结构。基于不同的端口启动多个实例。
1.新建3307实例的文件目录
#cd /data/
#mkdir -p /data/mysqldata/{3307/{data,tmp,binlog,innodb_ts,innodb_log},backup,script
#chown -R mysql:mysql mysqldata
#su - mysql
2.使用新的mysql.cnf文件启动mysql实例
[client]
port = 3307
socket = /data/mysqldata/3307/mysql.sock
# The MySQL server
[mysqld]
port = 3307
mysqlx_port = 33070
user = mysql
socket = /data/mysqldata/3307/mysql.sock
mysqlx_socket=/data/mysqldata/3307/mysqlx.sock
pid-file = /data/mysqldata/3307/mysql.pid
basedir = /usr/local/mysql
datadir = /data/mysqldata/3307/data
tmpdir = /data/mysqldata/3307/tmp
open_files_limit = 60000
explicit_defaults_for_timestamp
server-id = 1203307
lower_case_table_names = 1
character-set-server = utf8
federated
#sql_mode=STRICT_TRANS_TABLES
max_connections = 1000
max_connect_errors = 100000
interactive_timeout = 86400
wait_timeout = 86400
back_log=100
default-storage-engine = InnoDB
#*********** GTID settting*******************
log_slave_updates = 1
gtid_mode=ON
enforce-gtid-consistency=true
innodb_flush_log_at_trx_commit=2
binlog_format= row
skip-slave-start=1
sync_binlog=5
#*********** Logs related settings ***********
log-bin = /data/mysqldata/3307/binlog/mysql-bin
binlog_cache_size=32m
max_binlog_cache_size=64m
max_binlog_size=512m
long_query_time = 1
log_output = FILE
log-error = /data/mysqldata/3307/mysql-error.log
slow_query_log = 1
slow_query_log_file = /data/mysqldata/3307/slow_statement.log
#log_queries_not_using_indexes
general_log = 0
general_log_file = /data/mysqldata/3307/general_statement.log
#expire-logs-days = 14
binlog_expire_logs_seconds = 1728000
relay-log = /data/mysqldata/3307/binlog/relay-bin
relay-log-index = /data/mysqldata/3307/binlog/relay-bin.index
#****** MySQL Replication New Feature*********
master-info-repository=TABLE
relay-log-info-repository=TABLE
relay-log-recovery
#*********** INNODB Specific options ***********
innodb_buffer_pool_size = 2048M
transaction-isolation=REPEATABLE-READ
innodb_buffer_pool_instances = 8
innodb_file_per_table = 1
innodb_data_home_dir = /data/mysqldata/3307/innodb_ts
innodb_data_file_path = ibdata1:2048M:autoextend
innodb_thread_concurrency = 8
innodb_log_buffer_size = 16M
innodb_log_file_size = 128M
innodb_log_files_in_group = 3
innodb_log_group_home_dir = /data/mysqldata/3307/innodb_log
innodb_flush_log_at_trx_commit = 2
innodb_max_dirty_pages_pct = 70
innodb_flush_method=O_DIRECT
[mysql]
no-auto-rehash
default-character-set=gbk
prompt = (u@h) [d]>\_
3.初始化数据库
$/usr/local/mysql/bin/mysqld --defaults-file=/data/mysqldata/3307/my.cnf --initialize --user=mysql
4.启动数据库
$/usr/local/mysql/bin/mysqld_safe --defaults-file=/data/mysqldata/3307/my.cnf --user=mysql &
5.多实例配置过程中的一些问题总结
- error日志报错明细(一):
2018-06-01T06:49:48.544169Z 0 [ERROR] [MY-011292] [Server] Plugin mysqlx reported: 'Preparation of I/O interfaces failed, X Protocol won't be accessible'
2018-06-01T06:49:48.544429Z 0 [ERROR] [MY-011300] [Server] Plugin mysqlx reported: 'Setup of UNIX socket (/data/mysqldata/3306/mysqlx.sock) failed, another
process with PID 17095 is using UNIX socket file'
- 解决思路
1.查看socket值 (root@localhost) [(none)]> show variables like '%socket%' ;
+-----------------------------------------+----------------------------------+
| Variable_name | Value |
+-----------------------------------------+----------------------------------+
| mysqlx_socket | /data/mysqldata/3306/mysqlx.sock |
| performance_schema_max_socket_classes | 10 |
| performance_schema_max_socket_instances | -1 |
| socket | /data/mysqldata/3307/mysql.sock |
+---------------------------------------+----------------------------------+
2.编译mysql源码的时候,需指定了MYSQLX_UNIX_ADDR的值。修改mysqlx_socket配置mysqlx_socket=/data/mysqldata/3307/mysqlx.sock
- error日志报错明细(二):
2018-06-01T07:10:47.051235Z 0 [ERROR] [MY-011300] [Server] Plugin mysqlx reported: 'Setup of TCP (bind-address:'*', port:33060) failed, `bind()` failed with
error: Address already in use (98). Do you already have another mysqld server running with Mysqlx ?'
- 解决思路
1.查看port值 (root@localhost) [(none)]> show variables like '%port%';
+--------------------------+-------+
| Variable_name | Value |
+--------------------------+-------+
| large_files_support | ON |
| mysqlx_port | 33060 |
| mysqlx_port_open_timeout | 0 |
| port | 3307 |
| report_host | |
| report_password | |
| report_port | 3307 |
| report_user | |
| require_secure_transport | OFF |
+--------------------------+-------+
2.修改mysql.cnf文件mysqlx_port = 33070
这样数据库重启启动,不会报错。两个实例的MySQL的条件具备,可以搭建基于GTID的主从。