• linux上启动mysql失败


    1、提示异常信息为:Starting MySQL.The server quit without updating PID file (/var/lib/mysql/iZ25g67a3c5Z.pid).[FAILED]

    2、查看日志文件iZ25g67a3c5Z.err  显示错误日志为:


    140915 10:13:47 mysqld_safe mysqld from pid file /var/lib/mysql/iZ25g67a3c5Z.pid ended
    140915 10:15:00 mysqld_safe Starting mysqld daemon with databases from /var/lib/mysql
    140915 10:15:00 [Note] Plugin 'FEDERATED' is disabled.
    140915 10:15:00 InnoDB: The InnoDB memory heap is disabled
    140915 10:15:00 InnoDB: Mutexes and rw_locks use GCC atomic builtins
    140915 10:15:00 InnoDB: Compressed tables use zlib 1.2.3
    140915 10:15:00 InnoDB: Using Linux native AIO
    140915 10:15:00 InnoDB: Initializing buffer pool, size = 128.0M
    InnoDB: mmap(137363456 bytes) failed; errno 12
    140915 10:15:00 InnoDB: Completed initialization of buffer pool
    140915 10:15:00 InnoDB: Fatal error: cannot allocate memory for the buffer pool
    140915 10:15:00 [ERROR] Plugin 'InnoDB' init function returned error.
    140915 10:15:00 [ERROR] Plugin 'InnoDB' registration as a STORAGE ENGINE failed.
    140915 10:15:00 [ERROR] Unknown/unsupported storage engine: InnoDB
    140915 10:15:00 [ERROR] Aborting

    140915 10:15:00 [Note] /usr/sbin/mysqld: Shutdown complete

    3、解决方法:

    这个其实日志里面说的很明白就是 mysql要占用内存的时候 物理内存不够用导致的 所有 vim /etc/my.cnf

    [inonodb]

    innodb_buffer_pool_size=64MB  把这个数值改小 高版本的默认是128mb  版本的默认是8Mb