• 新增职责 不能从IE进入的问题 此责任无可用函数 (转)


    此责任无可用函数(The Function Is Not Available Under The Responsibility)

    When attempting to navigate to a function which has been newly added to a menu the following error occurs:

    ERROR

    The <Function Name> Function Is Not Available Under The <Responsibility Name> Responsibility

    STEPS

    The issue can be reproduced at will with the following steps:

    1. Query menu: <Menu Name>,

    2. Add function: <Function Name> and Save.

    3. Verify that the menu compilation request (FNDSCMPI module: Compile Security) completed successfully.

    4. Log into e-Business Suite and try to navigate to function: <Function Name>.

    5. The error occurs.

    This issue is caused by launching the menu item before the Compile Security has completed. When a function is added to a menu , a concurrent program ‘Compile Security’ is submitted which loads the data in Fnd_Compiled_Menu_Functions table. Whenever a function is accessed, security code checks Fnd_Compiled_Menu_Functions table to determine whether that function is accessible under the given security context or not. So if this function is accessed before the ‘Compile Security’ program is finished, the function cache gets loaded with stale data and the reported error message is thrown.

    So after modifying the 2 menu definitions associated with ‘System Administrator’ and ‘Application Developer’ make sure that 2 concurrent requests submitted for the above 2 modifications completed normally and then try to access the functions.

    Further once this error occurs, it will be cached which means that even after the menu item has been flagged as available, it the error will be returned from the cache.

    — Solution —–

    – To implement the solution, please execute the following steps::

    1) Manually run the ‘Compile Security’ concurrent program, set the parameter to YES.  运行请求  编译安全性

    2) Shut down Middle Tier (Apache)

    3) Delete the contents of $OA_HTML/_pages directory (11.5.10 only).

    4) Restart Middle tier

    5) Test the menu item

    是由于$CUX_TOP没设置引起的,解决方法:

    1.打开$CONTEXT_FILE(即/ebs12/VIS/inst/apps/VIS_erp/appl/admin/VIS_erp.xml)

     找到GL_TOP子句,在它后面加上

    <CUX_TOP oa_var="s_cuxtop" oa_type="PROD_TOP" oa_enabled="FALSE">/ebs12/VIS/apps/apps_st/appl/cux/12.0.0</CUX_TOP>

    2.到$ADMIN_SCRIPTS_HOME(即apache脚本运行目录:/ebs12/VIS/inst/apps/VIS_erp/admin/scripts),重新配置

    adautocfg.sh apps/apps

  • 相关阅读:
    HTML5 ViewPort 资料收集
    [ASP.NET 技术点滴] Jquery 前端验证
    [转帖]Asp.NET 弹出页面
    [转]ASP.NET 页生命周期概述
    C#时间转整型(时间戳),模仿php strtotime函数的部分功能
    [转]使用微软的官方类库CHSPinYinConv获得汉字拼音
    [转]ASP.NET数据库连接字符串总结
    gradle 生成 pom,引用mybatis-plus源代码到自己的工程中
    困扰的问题终于解决了-docker时区不正确的问题修改记
    mybatis plus3.1.0 热加载mapper
  • 原文地址:https://www.cnblogs.com/toowang/p/10648393.html
Copyright © 2020-2023  润新知