• sqlserver 误删数据恢复


    ----创建存储过程

    CREATE PROCEDURE Recover_Deleted_Data_Proc
        @Database_Name NVARCHAR(MAX) ,
        @SchemaName_n_TableName NVARCHAR(MAX) ,
        @Date_From DATETIME = '1900/01/01' ,
        @Date_To DATETIME = '9999/12/31'
    AS
        DECLARE @RowLogContents VARBINARY(8000)
        DECLARE @TransactionID NVARCHAR(MAX)
        DECLARE @AllocUnitID BIGINT
        DECLARE @AllocUnitName NVARCHAR(MAX)
        DECLARE @SQL NVARCHAR(MAX)
        DECLARE @Compatibility_Level INT
     
     
        SELECT  @Compatibility_Level = dtb.compatibility_level
        FROM    master.sys.databases AS dtb
        WHERE   dtb.name = @Database_Name
     
        IF ISNULL(@Compatibility_Level, 0) <= 80
            BEGIN
                RAISERROR('The compatibility level should be equal to or greater SQL SERVER 2005 (90)',16,1)
                RETURN
            END
     
        IF ( SELECT COUNT(*)
             FROM   INFORMATION_SCHEMA.TABLES
             WHERE  [TABLE_SCHEMA] + '.' + [TABLE_NAME] = @SchemaName_n_TableName
           ) = 0
            BEGIN
                RAISERROR('Could not found the table in the defined database',16,1)
                RETURN
            END
     
        DECLARE @bitTable TABLE
            (
              [ID] INT ,
              [Bitvalue] INT
            )
    --Create table to set the bit position of one byte.
     
        INSERT  INTO @bitTable
                SELECT  0 ,
                        2
                UNION ALL
                SELECT  1 ,
                        2
                UNION ALL
                SELECT  2 ,
                        4
                UNION ALL
                SELECT  3 ,
                        8
                UNION ALL
                SELECT  4 ,
                        16
                UNION ALL
                SELECT  5 ,
                        32
                UNION ALL
                SELECT  6 ,
                        64
                UNION ALL
                SELECT  7 ,
                        128
     
    --Create table to collect the row data.
        DECLARE @DeletedRecords TABLE
            (
              [Row ID] INT IDENTITY(1, 1) ,
              [RowLogContents] VARBINARY(8000) ,
              [AllocUnitID] BIGINT ,
              [Transaction ID] NVARCHAR(MAX) ,
              [FixedLengthData] SMALLINT ,
              [TotalNoOfCols] SMALLINT ,
              [NullBitMapLength] SMALLINT ,
              [NullBytes] VARBINARY(8000) ,
              [TotalNoofVarCols] SMALLINT ,
              [ColumnOffsetArray] VARBINARY(8000) ,
              [VarColumnStart] SMALLINT ,
              [Slot ID] INT ,
              [NullBitMap] VARCHAR(MAX)
            )
    --Create a common table expression to get all the row data plus how many bytes we have for each row.
    ;
        WITH    RowData
                  AS ( SELECT   [RowLog Contents 0] AS [RowLogContents] ,
                                [AllocUnitID] AS [AllocUnitID] ,
                                [Transaction ID] AS [Transaction ID]  
     
    --[Fixed Length Data] = Substring (RowLog content 0, Status Bit A+ Status Bit B + 1,2 bytes)
                                ,
                                CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) AS [FixedLengthData]  --@FixedLengthData
     
    -- [TotalnoOfCols] =  Substring (RowLog content 0, [Fixed Length Data] + 1,2 bytes)
                                ,
                                CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 1,
                                                                  2)))) AS [TotalNoOfCols]
     
    --[NullBitMapLength]=ceiling([Total No of Columns] /8.0)
                                ,
                                CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 1,
                                                                  2)))) / 8.0)) AS [NullBitMapLength] 
     
    --[Null Bytes] = Substring (RowLog content 0, Status Bit A+ Status Bit B + [Fixed Length Data] +1, [NullBitMapLength] )
                                ,
                                SUBSTRING([RowLog Contents 0],
                                          CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 3,
                                          CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 1,
                                                                  2)))) / 8.0))) AS [NullBytes]
     
    --[TotalNoofVarCols] = Substring (RowLog content 0, Status Bit A+ Status Bit B + [Fixed Length Data] +1, [Null Bitmap length] + 2 )
                                ,
                                ( CASE WHEN SUBSTRING([RowLog Contents 0], 1, 1) IN (
                                            0x10, 0x30, 0x70 )
                                       THEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 3
                                                                  + CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 1,
                                                                  2)))) / 8.0)), 2))))
                                       ELSE NULL
                                  END ) AS [TotalNoofVarCols] 
     
    --[ColumnOffsetArray]= Substring (RowLog content 0, Status Bit A+ Status Bit B + [Fixed Length Data] +1, [Null Bitmap length] + 2 , [TotalNoofVarCols]*2 )
                                ,
                                ( CASE WHEN SUBSTRING([RowLog Contents 0], 1, 1) IN (
                                            0x10, 0x30, 0x70 )
                                       THEN SUBSTRING([RowLog Contents 0],
                                                      CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 3
                                                      + CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 1,
                                                                  2)))) / 8.0))
                                                      + 2,
                                                      ( CASE WHEN SUBSTRING([RowLog Contents 0],
                                                                  1, 1) IN ( 0x10,
                                                                  0x30, 0x70 )
                                                             THEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 3
                                                                  + CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 1,
                                                                  2)))) / 8.0)), 2))))
                                                             ELSE NULL
                                                        END ) * 2)
                                       ELSE NULL
                                  END ) AS [ColumnOffsetArray] 
     
    --  Variable column Start = Status Bit A+ Status Bit B + [Fixed Length Data] + [Null Bitmap length] + 2+([TotalNoofVarCols]*2)
                                ,
                                CASE WHEN SUBSTRING([RowLog Contents 0], 1, 1) IN (
                                          0x10, 0x30, 0x70 )
                                     THEN ( CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 4
                                            + CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 1,
                                                                  2)))) / 8.0))
                                            + ( ( CASE WHEN SUBSTRING([RowLog Contents 0],
                                                                  1, 1) IN ( 0x10,
                                                                  0x30, 0x70 )
                                                       THEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 3
                                                                  + CONVERT(INT, CEILING(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  2 + 1, 2)))) + 1,
                                                                  2)))) / 8.0)), 2))))
                                                       ELSE NULL
                                                  END ) * 2 ) )
                                     ELSE NULL
                                END AS [VarColumnStart] ,
                                [Slot ID]
                       FROM     sys.fn_dblog(NULL, NULL)
                       WHERE    AllocUnitId IN (
                                SELECT  [Allocation_unit_id]
                                FROM    sys.allocation_units allocunits
                                        INNER JOIN sys.partitions partitions ON ( allocunits.type IN (
                                                                  1, 3 )
                                                                  AND partitions.hobt_id = allocunits.container_id
                                                                  )
                                                                  OR ( allocunits.type = 2
                                                                  AND partitions.partition_id = allocunits.container_id
                                                                  )
                                WHERE   object_id = OBJECT_ID(''
                                                              + @SchemaName_n_TableName
                                                              + '') )
                                AND Context IN ( 'LCX_MARK_AS_GHOST', 'LCX_HEAP' )
                                AND Operation IN ( 'LOP_DELETE_ROWS' )
                                AND SUBSTRING([RowLog Contents 0], 1, 1) IN ( 0x10,
                                                                  0x30, 0x70 )
     
    /*Use this subquery to filter the date*/
                                AND [TRANSACTION ID] IN (
                                SELECT DISTINCT
                                        [TRANSACTION ID]
                                FROM    sys.fn_dblog(NULL, NULL)
                                WHERE   Context IN ( 'LCX_NULL' )
                                        AND Operation IN ( 'LOP_BEGIN_XACT' )
                                        AND [Transaction Name] IN ( 'DELETE',
                                                                  'user_transaction' )
                                        AND CONVERT(NVARCHAR(11), [Begin Time]) BETWEEN @Date_From
                                                                  AND
                                                                  @Date_To )
                     ),
     
    --Use this technique to repeate the row till the no of bytes of the row.
                N1 ( n )
                  AS ( SELECT   1
                       UNION ALL
                       SELECT   1
                     ),
                N2 ( n )
                  AS ( SELECT   1
                       FROM     N1 AS X ,
                                N1 AS Y
                     ),
                N3 ( n )
                  AS ( SELECT   1
                       FROM     N2 AS X ,
                                N2 AS Y
                     ),
                N4 ( n )
                  AS ( SELECT   ROW_NUMBER() OVER ( ORDER BY X.n )
                       FROM     N3 AS X ,
                                N3 AS Y
                     )
            INSERT  INTO @DeletedRecords
                    SELECT  RowLogContents ,
                            [AllocUnitID] ,
                            [Transaction ID] ,
                            [FixedLengthData] ,
                            [TotalNoOfCols] ,
                            [NullBitMapLength] ,
                            [NullBytes] ,
                            [TotalNoofVarCols] ,
                            [ColumnOffsetArray] ,
                            [VarColumnStart] ,
                            [Slot ID]
             ---Get the Null value against each column (1 means null zero means not null)
                            ,
                            [NullBitMap] = ( REPLACE(STUFF(( SELECT
                                                                  ','
                                                                  + ( CASE
                                                                  WHEN [ID] = 0
                                                                  THEN CONVERT(NVARCHAR(1), ( SUBSTRING(NullBytes,
                                                                  n, 1) % 2 ))
                                                                  ELSE CONVERT(NVARCHAR(1), ( ( SUBSTRING(NullBytes,
                                                                  n, 1)
                                                                  / [Bitvalue] )
                                                                  % 2 ))
                                                                  END ) --as [nullBitMap]
                                                             FROM N4 AS Nums
                                                                  JOIN RowData AS C ON n <= NullBitMapLength
                                                                  CROSS JOIN @bitTable
                                                             WHERE
                                                                  C.[RowLogContents] = D.[RowLogContents]
                                                             ORDER BY [RowLogContents] ,
                                                                  n ASC
                                                           FOR
                                                             XML PATH('')
                                                           ), 1, 1, ''), ',', '') )
                    FROM    RowData D
     
        IF ( SELECT COUNT(*)
             FROM   @DeletedRecords
           ) = 0
            BEGIN
                RAISERROR('There is no data in the log as per the search criteria',16,1)
                RETURN
            END
     
        DECLARE @ColumnNameAndData TABLE
            (
              [Row ID] INT ,
              [Rowlogcontents] VARBINARY(MAX) ,
              [NAME] SYSNAME ,
              [nullbit] SMALLINT ,
              [leaf_offset] SMALLINT ,
              [length] SMALLINT ,
              [system_type_id] TINYINT ,
              [bitpos] TINYINT ,
              [xprec] TINYINT ,
              [xscale] TINYINT ,
              [is_null] INT ,
              [Column value Size] INT ,
              [Column Length] INT ,
              [hex_Value] VARBINARY(MAX) ,
              [Slot ID] INT ,
              [Update] INT
            )
     
    --Create common table expression and join it with the rowdata table
    -- to get each column details
    /*This part is for variable data columns*/
    --@RowLogContents, 
    --(col.columnOffValue - col.columnLength) + 1,
    --col.columnLength
    --)
        INSERT  INTO @ColumnNameAndData
                SELECT  [Row ID] ,
                        Rowlogcontents ,
                        NAME ,
                        cols.leaf_null_bit AS nullbit ,
                        leaf_offset ,
                        ISNULL(syscolumns.length, cols.max_length) AS [length] ,
                        cols.system_type_id ,
                        cols.leaf_bit_position AS bitpos ,
                        ISNULL(syscolumns.xprec, cols.precision) AS xprec ,
                        ISNULL(syscolumns.xscale, cols.scale) AS xscale ,
                        SUBSTRING([nullBitMap], cols.leaf_null_bit, 1) AS is_null ,
                        ( CASE WHEN leaf_offset < 1
                                    AND SUBSTRING([nullBitMap], cols.leaf_null_bit,
                                                  1) = 0
                               THEN ( CASE WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) > 30000
                                           THEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2))))
                                                - POWER(2, 15)
                                           ELSE CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2))))
                                      END )
                          END ) AS [Column value Size] ,
                        ( CASE WHEN leaf_offset < 1
                                    AND SUBSTRING([nullBitMap], cols.leaf_null_bit,
                                                  1) = 0
                               THEN ( CASE WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) > 30000
                                                AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                           [varColumnStart]) < 30000
                                           THEN ( CASE WHEN [System_type_id] IN (
                                                            35, 34, 99 ) THEN 16
                                                       ELSE 24
                                                  END )
                                           WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) > 30000
                                                AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                           [varColumnStart]) > 30000
                                           THEN ( CASE WHEN [System_type_id] IN (
                                                            35, 34, 99 ) THEN 16
                                                       ELSE 24
                                                  END ) --24 
                                           WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) < 30000
                                                AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                           [varColumnStart]) < 30000
                                           THEN ( CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2))))
                                                  - ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                           [varColumnStart]) )
                                           WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) < 30000
                                                AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                           [varColumnStart]) > 30000
                                           THEN POWER(2, 15)
                                                + CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2))))
                                                - ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                         [varColumnStart])
                                      END )
                          END ) AS [Column Length] ,
                        ( CASE WHEN SUBSTRING([nullBitMap], cols.leaf_null_bit, 1) = 1
                               THEN NULL
                               ELSE SUBSTRING(Rowlogcontents,
                                              ( ( CASE WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) > 30000
                                                       THEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2))))
                                                            - POWER(2, 15)
                                                       ELSE CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2))))
                                                  END )
                                                - ( CASE WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) > 30000
                                                              AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                                  [varColumnStart]) < 30000
                                                         THEN ( CASE
                                                                  WHEN [System_type_id] IN (
                                                                  35, 34, 99 )
                                                                  THEN 16
                                                                  ELSE 24
                                                                END ) --24 
                                                         WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) > 30000
                                                              AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                                  [varColumnStart]) > 30000
                                                         THEN ( CASE
                                                                  WHEN [System_type_id] IN (
                                                                  35, 34, 99 )
                                                                  THEN 16
                                                                  ELSE 24
                                                                END ) --24 
                                                         WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) < 30000
                                                              AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                                  [varColumnStart]) < 30000
                                                         THEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2))))
                                                              - ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                                  [varColumnStart])
                                                         WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) < 30000
                                                              AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                                  [varColumnStart]) > 30000
                                                         THEN POWER(2, 15)
                                                              + CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2))))
                                                              - ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                                  [varColumnStart])
                                                    END ) ) + 1,
                                              ( CASE WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) > 30000
                                                          AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                                  [varColumnStart]) < 30000
                                                     THEN ( CASE WHEN [System_type_id] IN (
                                                                  35, 34, 99 )
                                                                 THEN 16
                                                                 ELSE 24
                                                            END ) --24 
                                                     WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) > 30000
                                                          AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                                  [varColumnStart]) > 30000
                                                     THEN ( CASE WHEN [System_type_id] IN (
                                                                  35, 34, 99 )
                                                                 THEN 16
                                                                 ELSE 24
                                                            END ) --24 
                                                     WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) < 30000
                                                          AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                                  [varColumnStart]) < 30000
                                                     THEN ABS(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2))))
                                                              - ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                                  [varColumnStart]))
                                                     WHEN CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2)))) < 30000
                                                          AND ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                                  [varColumnStart]) > 30000
                                                     THEN POWER(2, 15)
                                                          + CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * leaf_offset
                                                                  * -1 ) - 1, 2))))
                                                          - ISNULL(NULLIF(CONVERT(INT, CONVERT(BINARY(2), REVERSE(SUBSTRING([ColumnOffsetArray],
                                                                  ( 2
                                                                  * ( ( leaf_offset
                                                                  * -1 ) - 1 ) )
                                                                  - 1, 2)))), 0),
                                                                  [varColumnStart])
                                                END ))
                          END ) AS hex_Value ,
                        [Slot ID] ,
                        0
                FROM    @DeletedRecords A
                        INNER JOIN sys.allocation_units allocunits ON A.[AllocUnitId] = allocunits.[Allocation_Unit_Id]
                        INNER JOIN sys.partitions partitions ON ( allocunits.type IN (
                                                                  1, 3 )
                                                                  AND partitions.hobt_id = allocunits.container_id
                                                                )
                                                                OR ( allocunits.type = 2
                                                                  AND partitions.partition_id = allocunits.container_id
                                                                  )
                        INNER JOIN sys.system_internals_partition_columns cols ON cols.partition_id = partitions.partition_id
                        LEFT OUTER JOIN syscolumns ON syscolumns.id = partitions.object_id
                                                      AND syscolumns.colid = cols.partition_column_id
                WHERE   leaf_offset < 0
                UNION
    /*This part is for fixed data columns*/
                SELECT  [Row ID] ,
                        Rowlogcontents ,
                        NAME ,
                        cols.leaf_null_bit AS nullbit ,
                        leaf_offset ,
                        ISNULL(syscolumns.length, cols.max_length) AS [length] ,
                        cols.system_type_id ,
                        cols.leaf_bit_position AS bitpos ,
                        ISNULL(syscolumns.xprec, cols.precision) AS xprec ,
                        ISNULL(syscolumns.xscale, cols.scale) AS xscale ,
                        SUBSTRING([nullBitMap], cols.leaf_null_bit, 1) AS is_null ,
                        ( SELECT TOP 1
                                    ISNULL(SUM(CASE WHEN C.leaf_offset > 1
                                                    THEN max_length
                                                    ELSE 0
                                               END), 0)
                          FROM      sys.system_internals_partition_columns C
                          WHERE     cols.partition_id = C.partition_id
                                    AND C.leaf_null_bit < cols.leaf_null_bit
                        ) + 5 AS [Column value Size] ,
                        syscolumns.length AS [Column Length] ,
                        CASE WHEN SUBSTRING([nullBitMap], cols.leaf_null_bit, 1) = 1
                             THEN NULL
                             ELSE SUBSTRING(Rowlogcontents,
                                            ( SELECT TOP 1
                                                        ISNULL(SUM(CASE
                                                                  WHEN C.leaf_offset > 1
                                                                  AND C.leaf_bit_position = 0
                                                                  THEN max_length
                                                                  ELSE 0
                                                                  END), 0)
                                              FROM      sys.system_internals_partition_columns C
                                              WHERE     cols.partition_id = C.partition_id
                                                        AND C.leaf_null_bit < cols.leaf_null_bit
                                            ) + 5, syscolumns.length)
                        END AS hex_Value ,
                        [Slot ID] ,
                        0
                FROM    @DeletedRecords A
                        INNER JOIN sys.allocation_units allocunits ON A.[AllocUnitId] = allocunits.[Allocation_Unit_Id]
                        INNER JOIN sys.partitions partitions ON ( allocunits.type IN (
                                                                  1, 3 )
                                                                  AND partitions.hobt_id = allocunits.container_id
                                                                )
                                                                OR ( allocunits.type = 2
                                                                  AND partitions.partition_id = allocunits.container_id
                                                                  )
                        INNER JOIN sys.system_internals_partition_columns cols ON cols.partition_id = partitions.partition_id
                        LEFT OUTER JOIN syscolumns ON syscolumns.id = partitions.object_id
                                                      AND syscolumns.colid = cols.partition_column_id
                WHERE   leaf_offset > 0
                ORDER BY nullbit
     
        DECLARE @BitColumnByte AS INT
        SELECT  @BitColumnByte = CONVERT(INT, CEILING(COUNT(*) / 8.0))
        FROM    @ColumnNameAndData
        WHERE   [System_Type_id] = 104;
        WITH    N1 ( n )
                  AS ( SELECT   1
                       UNION ALL
                       SELECT   1
                     ),
                N2 ( n )
                  AS ( SELECT   1
                       FROM     N1 AS X ,
                                N1 AS Y
                     ),
                N3 ( n )
                  AS ( SELECT   1
                       FROM     N2 AS X ,
                                N2 AS Y
                     ),
                N4 ( n )
                  AS ( SELECT   ROW_NUMBER() OVER ( ORDER BY X.n )
                       FROM     N3 AS X ,
                                N3 AS Y
                     ),
                CTE
                  AS ( SELECT   RowLogContents ,
                                [nullbit] ,
                                [BitMap] = CONVERT(VARBINARY(1), CONVERT(INT, SUBSTRING(( REPLACE(STUFF(( SELECT
                                                                  ','
                                                                  + ( CASE
                                                                  WHEN [ID] = 0
                                                                  THEN CONVERT(NVARCHAR(1), ( SUBSTRING(hex_Value,
                                                                  n, 1) % 2 ))
                                                                  ELSE CONVERT(NVARCHAR(1), ( ( SUBSTRING(hex_Value,
                                                                  n, 1)
                                                                  / [Bitvalue] )
                                                                  % 2 ))
                                                                  END ) --as [nullBitMap]
                                                                  FROM
                                                                  N4 AS Nums
                                                                  JOIN @ColumnNameAndData
                                                                  AS C ON n <= @BitColumnByte
                                                                  AND [System_Type_id] = 104
                                                                  AND bitpos = 0
                                                                  CROSS JOIN @bitTable
                                                                  WHERE
                                                                  C.[RowLogContents] = D.[RowLogContents]
                                                                  ORDER BY [RowLogContents] ,
                                                                  n ASC
                                                                  FOR
                                                                  XML
                                                                  PATH('')
                                                                  ), 1, 1, ''),
                                                                  ',', '') ),
                                                                  bitpos + 1, 1)))
                       FROM     @ColumnNameAndData D
                       WHERE    [System_Type_id] = 104
                     )
            UPDATE  A
            SET     [hex_Value] = [BitMap]
            FROM    @ColumnNameAndData A
                    INNER JOIN CTE B ON A.[RowLogContents] = B.[RowLogContents]
                                        AND A.[nullbit] = B.[nullbit]
     
     
    /**************Check for BLOB DATA TYPES******************************/
        DECLARE @Fileid INT
        DECLARE @Pageid INT
        DECLARE @Slotid INT
        DECLARE @CurrentLSN INT
        DECLARE @LinkID INT
        DECLARE @Context VARCHAR(50)
        DECLARE @ConsolidatedPageID VARCHAR(MAX)
        DECLARE @LCX_TEXT_MIX VARBINARY(MAX)
     
        DECLARE @temppagedata TABLE
            (
              [ParentObject] SYSNAME ,
              [Object] SYSNAME ,
              [Field] SYSNAME ,
              [Value] SYSNAME
            )
     
        DECLARE @pagedata TABLE
            (
              [Page ID] SYSNAME ,
              [File IDS] INT ,
              [Page IDS] INT ,
              [AllocUnitId] BIGINT ,
              [ParentObject] SYSNAME ,
              [Object] SYSNAME ,
              [Field] SYSNAME ,
              [Value] SYSNAME
            )
     
        DECLARE @ModifiedRawData TABLE
            (
              [ID] INT IDENTITY(1, 1) ,
              [PAGE ID] VARCHAR(MAX) ,
              [FILE IDS] INT ,
              [PAGE IDS] INT ,
              [Slot ID] INT ,
              [AllocUnitId] BIGINT ,
              [RowLog Contents 0_var] VARCHAR(MAX) ,
              [RowLog Length] VARCHAR(50) ,
              [RowLog Len] INT ,
              [RowLog Contents 0] VARBINARY(MAX) ,
              [Link ID] INT DEFAULT ( 0 ) ,
              [Update] INT
            )
     
        DECLARE Page_Data_Cursor CURSOR
        FOR
            /*We need to filter LOP_MODIFY_ROW,LOP_MODIFY_COLUMNS from log for deleted records of BLOB data type& Get its Slot No, Page ID & AllocUnit ID*/
                SELECT  LTRIM(RTRIM(REPLACE([Description], 'Deallocated', ''))) AS [PAGE ID] ,
                        [Slot ID] ,
                        [AllocUnitId] ,
                        NULL AS [RowLog Contents 0] ,
                        NULL AS [RowLog Contents 0] ,
                        Context
                FROM    sys.fn_dblog(NULL, NULL)
                WHERE   AllocUnitId IN (
                        SELECT  [Allocation_unit_id]
                        FROM    sys.allocation_units allocunits
                                INNER JOIN sys.partitions partitions ON ( allocunits.type IN (
                                                                  1, 3 )
                                                                  AND partitions.hobt_id = allocunits.container_id
                                                                  )
                                                                  OR ( allocunits.type = 2
                                                                  AND partitions.partition_id = allocunits.container_id
                                                                  )
                        WHERE   object_id = OBJECT_ID('' + @SchemaName_n_TableName
                                                      + '') )
                        AND Operation IN ( 'LOP_MODIFY_ROW' )
                        AND [Context] IN ( 'LCX_PFS' )
                        AND Description LIKE '%Deallocated%'
                /*Use this subquery to filter the date*/
                        AND [TRANSACTION ID] IN (
                        SELECT DISTINCT
                                [TRANSACTION ID]
                        FROM    sys.fn_dblog(NULL, NULL)
                        WHERE   Context IN ( 'LCX_NULL' )
                                AND Operation IN ( 'LOP_BEGIN_XACT' )
                                AND [Transaction Name] = 'DELETE'
                                AND CONVERT(NVARCHAR(11), [Begin Time]) BETWEEN @Date_From
                                                                  AND
                                                                  @Date_To )
                GROUP BY [Description] ,
                        [Slot ID] ,
                        [AllocUnitId] ,
                        Context
                UNION
                SELECT  [PAGE ID] ,
                        [Slot ID] ,
                        [AllocUnitId] ,
                        SUBSTRING([RowLog Contents 0], 15,
                                  LEN([RowLog Contents 0])) AS [RowLog Contents 0] ,
                        CONVERT(INT, SUBSTRING([RowLog Contents 0], 7, 2)) ,
                        Context --,CAST(RIGHT([Current LSN],4) AS INT) AS [Current LSN]
                FROM    sys.fn_dblog(NULL, NULL)
                WHERE   AllocUnitId IN (
                        SELECT  [Allocation_unit_id]
                        FROM    sys.allocation_units allocunits
                                INNER JOIN sys.partitions partitions ON ( allocunits.type IN (
                                                                  1, 3 )
                                                                  AND partitions.hobt_id = allocunits.container_id
                                                                  )
                                                                  OR ( allocunits.type = 2
                                                                  AND partitions.partition_id = allocunits.container_id
                                                                  )
                        WHERE   object_id = OBJECT_ID('' + @SchemaName_n_TableName
                                                      + '') )
                        AND Context IN ( 'LCX_TEXT_MIX' )
                        AND Operation IN ( 'LOP_DELETE_ROWS' ) 
                /*Use this subquery to filter the date*/
                        AND [TRANSACTION ID] IN (
                        SELECT DISTINCT
                                [TRANSACTION ID]
                        FROM    sys.fn_dblog(NULL, NULL)
                        WHERE   Context IN ( 'LCX_NULL' )
                                AND Operation IN ( 'LOP_BEGIN_XACT' )
                                AND [Transaction Name] = 'DELETE'
                                AND CONVERT(NVARCHAR(11), [Begin Time]) BETWEEN @Date_From
                                                                  AND
                                                                  @Date_To )
                             
                /****************************************/
     
        OPEN Page_Data_Cursor
     
        FETCH NEXT FROM Page_Data_Cursor INTO @ConsolidatedPageID, @Slotid,
            @AllocUnitID, @LCX_TEXT_MIX, @LinkID, @Context
     
        WHILE @@FETCH_STATUS = 0
            BEGIN
                DECLARE @hex_pageid AS VARCHAR(MAX)
                /*Page ID contains File Number and page number It looks like 0001:00000130.
                  In this example 0001 is file Number &  00000130 is Page Number & These numbers are in Hex format*/
                SET @Fileid = SUBSTRING(@ConsolidatedPageID, 0,
                                        CHARINDEX(':', @ConsolidatedPageID)) -- Seperate File ID from Page ID
             
                SET @hex_pageid = '0x' + SUBSTRING(@ConsolidatedPageID,
                                                   CHARINDEX(':',
                                                             @ConsolidatedPageID)
                                                   + 1, LEN(@ConsolidatedPageID))  ---Seperate the page ID
                SELECT  @Pageid = CONVERT(INT, CAST('' AS XML).value('xs:hexBinary(substring(sql:variable("@hex_pageid"),sql:column("t.pos")) )',
                                                                  'varbinary(max)')) -- Convert Page ID from hex to integer
                FROM    ( SELECT    CASE SUBSTRING(@hex_pageid, 1, 2)
                                      WHEN '0x' THEN 3
                                      ELSE 0
                                    END
                        ) AS t ( pos ) 
                 
                IF @Context = 'LCX_PFS'
                    BEGIN
                        DELETE  @temppagedata
                        INSERT  INTO @temppagedata
                                EXEC
                                    ( 'DBCC PAGE(' + @DataBase_Name + ', '
                                      + @fileid + ', ' + @pageid
                                      + ', 1) with tableresults,no_infomsgs;'
                                    ); 
                        INSERT  INTO @pagedata
                                SELECT  @ConsolidatedPageID ,
                                        @fileid ,
                                        @pageid ,
                                        @AllocUnitID ,
                                        [ParentObject] ,
                                        [Object] ,
                                        [Field] ,
                                        [Value]
                                FROM    @temppagedata
                    END
                ELSE
                    IF @Context = 'LCX_TEXT_MIX'
                        BEGIN
                            INSERT  INTO @ModifiedRawData
                                    SELECT  @ConsolidatedPageID ,
                                            @fileid ,
                                            @pageid ,
                                            @Slotid ,
                                            @AllocUnitID ,
                                            NULL ,
                                            0 ,
                                            CONVERT(INT, CONVERT(VARBINARY, REVERSE(SUBSTRING(@LCX_TEXT_MIX,
                                                                  11, 2)))) ,
                                            @LCX_TEXT_MIX ,
                                            @LinkID ,
                                            0
                        END    
                FETCH NEXT FROM Page_Data_Cursor INTO @ConsolidatedPageID, @Slotid,
                    @AllocUnitID, @LCX_TEXT_MIX, @LinkID, @Context
            END
         
        CLOSE Page_Data_Cursor
        DEALLOCATE Page_Data_Cursor
     
        DECLARE @Newhexstring VARCHAR(MAX);
     
        --The data is in multiple rows in the page, so we need to convert it into one row as a single hex value.
        --This hex value is in string format
        INSERT  INTO @ModifiedRawData
                ( [PAGE ID] ,
                  [FILE IDS] ,
                  [PAGE IDS] ,
                  [Slot ID] ,
                  [AllocUnitId] ,
                  [RowLog Contents 0_var] ,
                  [RowLog Length]
                )
                SELECT  [Page ID] ,
                        [FILE IDS] ,
                        [PAGE IDS] ,
                        SUBSTRING([ParentObject],
                                  CHARINDEX('Slot', [ParentObject]) + 4,
                                  ( CHARINDEX('Offset', [ParentObject])
                                    - ( CHARINDEX('Slot', [ParentObject]) + 4 ) )
                                  - 2) AS [Slot ID] ,
                        [AllocUnitId] ,
                        SUBSTRING(( SELECT  REPLACE(STUFF(( SELECT
                                                                  REPLACE(SUBSTRING([Value],
                                                                  CHARINDEX(':',
                                                                  [Value]) + 1,
                                                                  CHARINDEX('',
                                                                  [Value])
                                                                  - CHARINDEX(':',
                                                                  [Value])), '',
                                                                  '')
                                                            FROM  @pagedata C
                                                            WHERE B.[Page ID] = C.[Page ID]
                                                                  AND SUBSTRING(B.[ParentObject],
                                                                  CHARINDEX('Slot',
                                                                  B.[ParentObject])
                                                                  + 4,
                                                                  ( CHARINDEX('Offset',
                                                                  B.[ParentObject])
                                                                  - ( CHARINDEX('Slot',
                                                                  B.[ParentObject])
                                                                  + 4 ) )) = SUBSTRING(C.[ParentObject],
                                                                  CHARINDEX('Slot',
                                                                  C.[ParentObject])
                                                                  + 4,
                                                                  ( CHARINDEX('Offset',
                                                                  C.[ParentObject])
                                                                  - ( CHARINDEX('Slot',
                                                                  C.[ParentObject])
                                                                  + 4 ) ))
                                                                  AND [Object] LIKE '%Memory Dump%'
                                                            ORDER BY '0x'
                                                                  + LEFT([Value],
                                                                  CHARINDEX(':',
                                                                  [Value]) - 1)
                                                          FOR
                                                            XML PATH('')
                                                          ), 1, 1, ''), ' ', '')
                                  ), 1, 20000) AS [Value] ,
                        SUBSTRING(( SELECT  '0x'
                                            + REPLACE(STUFF(( SELECT
                                                                  REPLACE(SUBSTRING([Value],
                                                                  CHARINDEX(':',
                                                                  [Value]) + 1,
                                                                  CHARINDEX('',
                                                                  [Value])
                                                                  - CHARINDEX(':',
                                                                  [Value])), '',
                                                                  '')
                                                              FROM
                                                                  @pagedata C
                                                              WHERE
                                                                  B.[Page ID] = C.[Page ID]
                                                                  AND SUBSTRING(B.[ParentObject],
                                                                  CHARINDEX('Slot',
                                                                  B.[ParentObject])
                                                                  + 4,
                                                                  ( CHARINDEX('Offset',
                                                                  B.[ParentObject])
                                                                  - ( CHARINDEX('Slot',
                                                                  B.[ParentObject])
                                                                  + 4 ) )) = SUBSTRING(C.[ParentObject],
                                                                  CHARINDEX('Slot',
                                                                  C.[ParentObject])
                                                                  + 4,
                                                                  ( CHARINDEX('Offset',
                                                                  C.[ParentObject])
                                                                  - ( CHARINDEX('Slot',
                                                                  C.[ParentObject])
                                                                  + 4 ) ))
                                                                  AND [Object] LIKE '%Memory Dump%'
                                                              ORDER BY '0x'
                                                                  + LEFT([Value],
                                                                  CHARINDEX(':',
                                                                  [Value]) - 1)
                                                            FOR
                                                              XML PATH('')
                                                            ), 1, 1, ''), ' ', '')
                                  ), 7, 4) AS [Length]
                FROM    @pagedata B
                WHERE   [Object] LIKE '%Memory Dump%'
                GROUP BY [Page ID] ,
                        [FILE IDS] ,
                        [PAGE IDS] ,
                        [ParentObject] ,
                        [AllocUnitId]--,[Current LSN]
                ORDER BY [Slot ID]
     
        UPDATE  @ModifiedRawData
        SET     [RowLog Len] = CONVERT(VARBINARY(8000), REVERSE(CAST('' AS XML).value('xs:hexBinary(substring(sql:column("[RowLog Length]"),0))',
                                                                  'varbinary(Max)')))
        FROM    @ModifiedRawData
        WHERE   [LINK ID] = 0
     
        UPDATE  @ModifiedRawData
        SET     [RowLog Contents 0] = CAST('' AS XML).value('xs:hexBinary(substring(sql:column("[RowLog Contents 0_var]"),0))',
                                                            'varbinary(Max)')
        FROM    @ModifiedRawData
        WHERE   [LINK ID] = 0
     
        UPDATE  B
        SET     B.[RowLog Contents 0] = ( CASE WHEN A.[RowLog Contents 0] IS NOT NULL
                                                    AND C.[RowLog Contents 0] IS NOT NULL
                                               THEN A.[RowLog Contents 0]
                                                    + C.[RowLog Contents 0]
                                               WHEN A.[RowLog Contents 0] IS NULL
                                                    AND C.[RowLog Contents 0] IS NOT NULL
                                               THEN C.[RowLog Contents 0]
                                               WHEN A.[RowLog Contents 0] IS NOT NULL
                                                    AND C.[RowLog Contents 0] IS NULL
                                               THEN A.[RowLog Contents 0]
                                          END ) ,
                B.[Update] = ISNULL(B.[Update], 0) + 1
        FROM    @ModifiedRawData B
                LEFT JOIN @ModifiedRawData A ON A.[Page IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],
                                                                  15 + 14, 2))))
                                                AND A.[File IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],
                                                                  19 + 14, 2))))
                                                AND A.[Link ID] = B.[Link ID]
                LEFT JOIN @ModifiedRawData C ON C.[Page IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],
                                                                  27 + 14, 2))))
                                                AND C.[File IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],
                                                                  31 + 14, 2))))
                                                AND C.[Link ID] = B.[Link ID]
        WHERE   ( A.[RowLog Contents 0] IS NOT NULL
                  OR C.[RowLog Contents 0] IS NOT NULL
                )
     
     
        UPDATE  B
        SET     B.[RowLog Contents 0] = ( CASE WHEN A.[RowLog Contents 0] IS NOT NULL
                                                    AND C.[RowLog Contents 0] IS NOT NULL
                                               THEN A.[RowLog Contents 0]
                                                    + C.[RowLog Contents 0]
                                               WHEN A.[RowLog Contents 0] IS NULL
                                                    AND C.[RowLog Contents 0] IS NOT NULL
                                               THEN C.[RowLog Contents 0]
                                               WHEN A.[RowLog Contents 0] IS NOT NULL
                                                    AND C.[RowLog Contents 0] IS NULL
                                               THEN A.[RowLog Contents 0]
                                          END )
        --,B.[Update]=ISNULL(B.[Update],0)+1
        FROM    @ModifiedRawData B
                LEFT JOIN @ModifiedRawData A ON A.[Page IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],
                                                                  15 + 14, 2))))
                                                AND A.[File IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],
                                                                  19 + 14, 2))))
                                                AND A.[Link ID] <> B.[Link ID]
                                                AND B.[Update] = 0
                LEFT JOIN @ModifiedRawData C ON C.[Page IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],
                                                                  27 + 14, 2))))
                                                AND C.[File IDS] = CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING(B.[RowLog Contents 0],
                                                                  31 + 14, 2))))
                                                AND C.[Link ID] <> B.[Link ID]
                                                AND B.[Update] = 0
        WHERE   ( A.[RowLog Contents 0] IS NOT NULL
                  OR C.[RowLog Contents 0] IS NOT NULL
                )
     
        UPDATE  @ModifiedRawData
        SET     [RowLog Contents 0] = ( CASE WHEN [RowLog Len] >= 8000
                                             THEN SUBSTRING([RowLog Contents 0],
                                                            15, [RowLog Len])
                                             WHEN [RowLog Len] < 8000
                                             THEN SUBSTRING([RowLog Contents 0],
                                                            15 + 6,
                                                            CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([RowLog Contents 0],
                                                                  15, 6)))))
                                        END )
        FROM    @ModifiedRawData
        WHERE   [LINK ID] = 0
     
        UPDATE  @ColumnNameAndData
        SET     [hex_Value] = [RowLog Contents 0] 
        --,A.[Update]=A.[Update]+1
        FROM    @ColumnNameAndData A
                INNER JOIN @ModifiedRawData B ON CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([hex_value],
                                                                  17, 4)))) = [PAGE IDS]
                                                 AND CONVERT(INT, SUBSTRING([hex_value],
                                                                  9, 2)) = B.[Link ID]
        WHERE   [System_Type_Id] IN ( 99, 167, 175, 231, 239, 241, 165, 98 )
                AND [Link ID] <> 0 
     
        UPDATE  @ColumnNameAndData
        SET     [hex_Value] = ( CASE WHEN B.[RowLog Contents 0] IS NOT NULL
                                          AND C.[RowLog Contents 0] IS NOT NULL
                                     THEN B.[RowLog Contents 0]
                                          + C.[RowLog Contents 0]
                                     WHEN B.[RowLog Contents 0] IS NULL
                                          AND C.[RowLog Contents 0] IS NOT NULL
                                     THEN C.[RowLog Contents 0]
                                     WHEN B.[RowLog Contents 0] IS NOT NULL
                                          AND C.[RowLog Contents 0] IS NULL
                                     THEN B.[RowLog Contents 0]
                                END )
        --,A.[Update]=A.[Update]+1
        FROM    @ColumnNameAndData A
                LEFT JOIN @ModifiedRawData B ON CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([hex_value],
                                                                  5, 4)))) = B.[PAGE IDS]
                                                AND B.[Link ID] = 0
                LEFT JOIN @ModifiedRawData C ON CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([hex_value],
                                                                  17, 4)))) = C.[PAGE IDS]
                                                AND C.[Link ID] = 0
        WHERE   [System_Type_Id] IN ( 99, 167, 175, 231, 239, 241, 165, 98 )
                AND ( B.[RowLog Contents 0] IS NOT NULL
                      OR C.[RowLog Contents 0] IS NOT NULL
                    )
     
        UPDATE  @ColumnNameAndData
        SET     [hex_Value] = [RowLog Contents 0] 
        --,A.[Update]=A.[Update]+1
        FROM    @ColumnNameAndData A
                INNER JOIN @ModifiedRawData B ON CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([hex_value],
                                                                  9, 4)))) = [PAGE IDS]
                                                 AND CONVERT(INT, SUBSTRING([hex_value],
                                                                  3, 2)) = [Link ID]
        WHERE   [System_Type_Id] IN ( 35, 34, 99 )
                AND [Link ID] <> 0 
         
        UPDATE  @ColumnNameAndData
        SET     [hex_Value] = [RowLog Contents 0]
        --,A.[Update]=A.[Update]+10
        FROM    @ColumnNameAndData A
                INNER JOIN @ModifiedRawData B ON CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([hex_value],
                                                                  9, 4)))) = [PAGE IDS]
        WHERE   [System_Type_Id] IN ( 35, 34, 99 )
                AND [Link ID] = 0
     
        UPDATE  @ColumnNameAndData
        SET     [hex_Value] = [RowLog Contents 0] 
        --,A.[Update]=A.[Update]+1
        FROM    @ColumnNameAndData A
                INNER JOIN @ModifiedRawData B ON CONVERT(INT, CONVERT(VARBINARY(MAX), REVERSE(SUBSTRING([hex_value],
                                                                  15, 4)))) = [PAGE IDS]
        WHERE   [System_Type_Id] IN ( 35, 34, 99 )
                AND [Link ID] = 0
     
        UPDATE  @ColumnNameAndData
        SET     [hex_value] = 0xFFFE + SUBSTRING([hex_value], 9, LEN([hex_value]))
        --,[Update]=[Update]+1
        WHERE   [system_type_id] = 241
     
        CREATE TABLE [#temp_Data]
            (
              [FieldName] VARCHAR(MAX) ,
              [FieldValue] NVARCHAR(MAX) ,
              [Rowlogcontents] VARBINARY(8000) ,
              [Row ID] INT
            )
     
        INSERT  INTO #temp_Data
                SELECT  NAME ,
                        CASE WHEN system_type_id IN ( 231, 239 )
                             THEN LTRIM(RTRIM(CONVERT(NVARCHAR(MAX), hex_Value)))  --NVARCHAR ,NCHAR
                             WHEN system_type_id IN ( 167, 175 )
                             THEN LTRIM(RTRIM(CONVERT(VARCHAR(MAX), hex_Value)))  --VARCHAR,CHAR
                             WHEN system_type_id IN ( 35 )
                             THEN LTRIM(RTRIM(CONVERT(VARCHAR(MAX), hex_Value))) --Text
                             WHEN system_type_id IN ( 99 )
                             THEN LTRIM(RTRIM(CONVERT(NVARCHAR(MAX), hex_Value))) --nText 
                             WHEN system_type_id = 48
                             THEN CONVERT(VARCHAR(MAX), CONVERT(TINYINT, CONVERT(BINARY(1), REVERSE(hex_Value)))) --TINY INTEGER
                             WHEN system_type_id = 52
                             THEN CONVERT(VARCHAR(MAX), CONVERT(SMALLINT, CONVERT(BINARY(2), REVERSE(hex_Value)))) --SMALL INTEGER
                             WHEN system_type_id = 56
                             THEN CONVERT(VARCHAR(MAX), CONVERT(INT, CONVERT(BINARY(4), REVERSE(hex_Value)))) -- INTEGER
                             WHEN system_type_id = 127
                             THEN CONVERT(VARCHAR(MAX), CONVERT(BIGINT, CONVERT(BINARY(8), REVERSE(hex_Value))))-- BIG INTEGER
                             WHEN system_type_id = 61
                             THEN CONVERT(VARCHAR(MAX), CONVERT(DATETIME, CONVERT(VARBINARY(8000), REVERSE(hex_Value))), 100) --DATETIME
                             WHEN system_type_id = 58
                             THEN CONVERT(VARCHAR(MAX), CONVERT(SMALLDATETIME, CONVERT(VARBINARY(8000), REVERSE(hex_Value))), 100) --SMALL DATETIME
                             WHEN system_type_id = 108
                             THEN CONVERT(VARCHAR(MAX), CONVERT(NUMERIC(38, 20), CONVERT(VARBINARY, CONVERT(VARBINARY(1), xprec)
                                  + CONVERT(VARBINARY(1), xscale))
                                  + CONVERT(VARBINARY(1), 0) + hex_Value)) --- NUMERIC
                             WHEN system_type_id = 106
                             THEN CONVERT(VARCHAR(MAX), CONVERT(DECIMAL(38, 20), CONVERT(VARBINARY, CONVERT(VARBINARY(1), xprec)
                                  + CONVERT(VARBINARY(1), xscale))
                                  + CONVERT(VARBINARY(1), 0) + hex_Value)) --- DECIMAL
                             WHEN system_type_id IN ( 60, 122 )
                             THEN CONVERT(VARCHAR(MAX), CONVERT(MONEY, CONVERT(VARBINARY(8000), REVERSE(hex_Value))), 2) --MONEY,SMALLMONEY
                             WHEN system_type_id = 104
                             THEN CONVERT(VARCHAR(MAX), CONVERT (BIT, CONVERT(BINARY(1), hex_Value)
                                  % 2))  -- BIT
                             WHEN system_type_id = 62
                             THEN RTRIM(LTRIM(STR(CONVERT(FLOAT, SIGN(CAST(CONVERT(VARBINARY(8000), REVERSE(hex_Value)) AS BIGINT))
                                                  * ( 1.0
                                                      + ( CAST(CONVERT(VARBINARY(8000), REVERSE(hex_Value)) AS BIGINT)
                                                          & 0x000FFFFFFFFFFFFF )
                                                      * POWER(CAST(2 AS FLOAT),
                                                              -52) )
                                                  * POWER(CAST(2 AS FLOAT),
                                                          ( ( CAST(CONVERT(VARBINARY(8000), REVERSE(hex_Value)) AS BIGINT)
                                                              & 0x7ff0000000000000 )
                                                            / EXP(52 * LOG(2))
                                                            - 1023 ))), 53,
                                                  LEN(hex_Value)))) --- FLOAT
                             WHEN system_type_id = 59
                             THEN LEFT(LTRIM(STR(CAST(SIGN(CAST(CONVERT(VARBINARY(8000), REVERSE(hex_Value)) AS BIGINT))
                                                 * ( 1.0
                                                     + ( CAST(CONVERT(VARBINARY(8000), REVERSE(hex_Value)) AS BIGINT)
                                                         & 0x007FFFFF )
                                                     * POWER(CAST(2 AS REAL), -23) )
                                                 * POWER(CAST(2 AS REAL),
                                                         ( ( ( CAST(CONVERT(VARBINARY(8000), REVERSE(hex_Value)) AS INT) )
                                                             & 0x7f800000 )
                                                           / EXP(23 * LOG(2))
                                                           - 127 )) AS REAL), 23,
                                                 23)), 8) --Real
                             WHEN system_type_id IN ( 165, 173 )
                             THEN ( CASE WHEN CHARINDEX(0x,
                                                        CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',
                                                                  'VARBINARY(8000)')) = 0
                                         THEN '0x'
                                         ELSE ''
                                    END ) + CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',
                                                                  'varchar(max)') -- BINARY,VARBINARY
                             WHEN system_type_id = 34
                             THEN ( CASE WHEN CHARINDEX(0x,
                                                        CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',
                                                                  'VARBINARY(8000)')) = 0
                                         THEN '0x'
                                         ELSE ''
                                    END ) + CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',
                                                                  'varchar(max)')  --IMAGE
                             WHEN system_type_id = 36
                             THEN CONVERT(VARCHAR(MAX), CONVERT(UNIQUEIDENTIFIER, hex_Value)) --UNIQUEIDENTIFIER
                             WHEN system_type_id = 231
                             THEN CONVERT(VARCHAR(MAX), CONVERT(SYSNAME, hex_Value)) --SYSNAME
                             WHEN system_type_id = 241
                             THEN CONVERT(VARCHAR(MAX), CONVERT(XML, hex_Value)) --XML
                             WHEN system_type_id = 189
                             THEN ( CASE WHEN CHARINDEX(0x,
                                                        CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',
                                                                  'VARBINARY(8000)')) = 0
                                         THEN '0x'
                                         ELSE ''
                                    END ) + CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',
                                                                  'varchar(max)') --TIMESTAMP
                             WHEN system_type_id = 98
                             THEN ( CASE WHEN CONVERT(INT, SUBSTRING(hex_Value, 1,
                                                                  1)) = 56
                                         THEN CONVERT(VARCHAR(MAX), CONVERT(INT, CONVERT(BINARY(4), REVERSE(SUBSTRING(hex_Value,
                                                                  3,
                                                                  LEN(hex_Value))))))  -- INTEGER
                                         WHEN CONVERT(INT, SUBSTRING(hex_Value, 1,
                                                                  1)) = 108
                                         THEN CONVERT(VARCHAR(MAX), CONVERT(NUMERIC(38,
                                                                  20), CONVERT(VARBINARY(1), SUBSTRING(hex_Value,
                                                                  3, 1))
                                              + CONVERT(VARBINARY(1), SUBSTRING(hex_Value,
                                                                  4, 1))
                                              + CONVERT(VARBINARY(1), 0)
                                              + SUBSTRING(hex_Value, 5,
                                                          LEN(hex_Value)))) --- NUMERIC
                                         WHEN CONVERT(INT, SUBSTRING(hex_Value, 1,
                                                                  1)) = 167
                                         THEN LTRIM(RTRIM(CONVERT(VARCHAR(MAX), SUBSTRING(hex_Value,
                                                                  9,
                                                                  LEN(hex_Value))))) --VARCHAR,CHAR
                                         WHEN CONVERT(INT, SUBSTRING(hex_Value, 1,
                                                                  1)) = 36
                                         THEN CONVERT(VARCHAR(MAX), CONVERT(UNIQUEIDENTIFIER, SUBSTRING(( hex_Value ),
                                                                  3, 20))) --UNIQUEIDENTIFIER
                                         WHEN CONVERT(INT, SUBSTRING(hex_Value, 1,
                                                                  1)) = 61
                                         THEN CONVERT(VARCHAR(MAX), CONVERT(DATETIME, CONVERT(VARBINARY(8000), REVERSE(SUBSTRING(hex_Value,
                                                                  3,
                                                                  LEN(hex_Value))))), 100) --DATETIME
                                         WHEN CONVERT(INT, SUBSTRING(hex_Value, 1,
                                                                  1)) = 165
                                         THEN '0x'
                                              + SUBSTRING(( CASE WHEN CHARINDEX(0x,
                                                                  CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',
                                                                  'VARBINARY(8000)')) = 0
                                                                 THEN '0x'
                                                                 ELSE ''
                                                            END )
                                                          + CAST('' AS XML).value('xs:hexBinary(sql:column("hex_Value"))',
                                                                  'varchar(max)'),
                                                          11, LEN(hex_Value)) -- BINARY,VARBINARY
                                    END )
                        END AS FieldValue ,
                        [Rowlogcontents] ,
                        [Row ID]
                FROM    @ColumnNameAndData
                ORDER BY nullbit
     
    --Create the column name in the same order to do pivot table.
     
        DECLARE @FieldName VARCHAR(MAX)
        SET @FieldName = STUFF(( SELECT ','
                                        + CAST(QUOTENAME([Name]) AS VARCHAR(MAX))
                                 FROM   syscolumns
                                 WHERE  id = OBJECT_ID(''
                                                       + @SchemaName_n_TableName
                                                       + '')
                               FOR
                                 XML PATH('')
                               ), 1, 1, '')
     
    --Finally did pivot table and get the data back in the same format.
     
        SET @sql = 'SELECT ' + @FieldName
            + ' FROM #temp_Data PIVOT (Min([FieldValue]) FOR FieldName IN ('
            + @FieldName + ')) AS pvt'
        EXEC sp_executesql @sql
     
    GO

    ---执行存储过程两个参数(数据库名,表名)

    EXEC Recover_Deleted_Data_Proc '数据库名称','dbo.tableName'--表名前面要加dbo 不然会报错的。

    --执行存储过程四个参数(数据库名称,表明,开始时间,结束时间【按照时间段来恢复】)

    EXEC Recover_Deleted_Data_Proc '数据库名称','dbo.TableName','2014-04-23','2014-04-23'--表名要加dbo。

    转自http://www.cnblogs.com/lyhabc/p/3683147.html#2924733.

  • 相关阅读:
    poj1113--凸包(Andrew)
    php变量内存完全释放
    php的内存分配还是很智能的
    git 忽略权限记录一下
    开启事务处理插入多条数据 速度也可以
    var_dump(is_writeable(ini_get("session.save_path")));
    要注意一下xss攻击啊
    select *," as A from B union ...
    多次踩坑
    js instanceof运算符
  • 原文地址:https://www.cnblogs.com/sunqiang/p/4344775.html
Copyright © 2020-2023  润新知