• sql优化案例(标量子查询改写)


    sql执行频繁,单次执行时间存在性能问题。
    sql如下:
    select t.cons_no,
    t.cons_name,
    t.elec_addr,
    t.contract_cap t_contract_cap,
    (select b.tg_id
    from s_mp_scheme b
    where exists (select 1
    from s_mp_app c
    where b.mp_scheme_id = c.mp_scheme_id
    and c.app_no = t.app_no)
    and rownum = 1) tg_id
    from s_app t
    where t.app_no = '2xxx7';


    Elapsed: 00:00:04.27

    Execution Plan
    ----------------------------------------------------------
    Plan hash value: 631761334


    Predicate Information (identified by operation id):
    ---------------------------------------------------

    1 - filter(ROWNUM=1)
    2 - filter( EXISTS (SELECT 0 FROM "SGPM"."S_MP_APP" "C" WHERE "C"."MP_SCHEME_
    ID"=:B1 AND

    "C"."APP_NO"=:B2))
    4 - filter("C"."APP_NO"=:B1)
    5 - access("C"."MP_SCHEME_ID"=:B1)
    7 - access("T"."APP_NO"='2xxx7')


    Statistics
    ----------------------------------------------------------
    0 recursive calls
    0 db block gets
    759983 consistent gets
    0 physical reads
    0 redo size
    906 bytes sent via SQL*Net to client
    519 bytes received via SQL*Net from client
    2 SQL*Net roundtrips to/from client
    0 sorts (memory)
    0 sorts (disk)
    1 rows processed

    从上面的Statistics我们发现一致读很多。
    执行计划S_MP_SCHEME也未能使用高效的扫描方式。
    由列的统计信息知道s_app表上的app_no选择性很高,返回的是少量的数据集。
    问题很明显:
    (select b.tg_id
    from s_mp_scheme b
    where exists (select 1
    from s_mp_app c
    where b.mp_scheme_id = c.mp_scheme_id
    and c.app_no = t.app_no)
    and rownum = 1)
    这段标量子查询导致性能问题,通过sql改写解决标量子查询的问题。

    sql改写后:
    select a.cons_no,
    a.cons_name,
    a.elec_addr,
    a.contract_cap t_contract_cap,
    d.tg_id
    from s_app a
    left join (
    select c.app_no,b.mp_scheme_id,max(tg_id) tg_id from s_mp_scheme b,s_mp_app c
    where b.mp_scheme_id = c.mp_scheme_id
    group by b.mp_scheme_id,c.app_no
    ) d
    on d.app_no = a.app_no
    where a.app_no = '2xxx7';
    Elapsed: 00:00:00.01

    Execution Plan
    ----------------------------------------------------------
    Plan hash value: 2090481196

    Predicate Information (identified by operation id):
    ---------------------------------------------------

    1 - access("D"."APP_NO"(+)="A"."APP_NO")
    3 - access("A"."APP_NO"='2xxx7')
    11 - access("C"."APP_NO"='2xxx7')
    12 - access("B"."MP_SCHEME_ID"="ITEM_1")


    Statistics
    ----------------------------------------------------------
    0 recursive calls
    0 db block gets
    7 consistent gets
    0 physical reads
    0 redo size
    906 bytes sent via SQL*Net to client
    519 bytes received via SQL*Net from client
    2 SQL*Net roundtrips to/from client
    0 sorts (memory)
    0 sorts (disk)
    1 rows processed

    原先的sqlconsistent gets为759983,改写后只有7。
    在生产环境中,标量子查询很容易出现性能问题,掌握对此类查询改写的方式很重要。

    改写标量子查询能让表的关联方式更加多样化,有助于产生更优的执行计划。