• CentOS7.2安装mysql-5.7.19多实例


    安装多实例之前首先需要先安装mysql,这里就不介绍如何安装mysql了,参考前面的博客:https://www.cnblogs.com/hei-ma/p/9505509.html

    安装多实例之前需要将之前安装好的mysql停掉。

    # /etc/init.d/mysqld stop

    开始正式安装mysql-5.7.19多实例

    1、创建多实例目录

    # mkdir -p /data/mysql{3307,3308}/data

    2、编辑多实例配置文件

          3308端口的需要将3307修改为3308,server-id也需要改

    # cat /data/mysql3307/my.cnf 
    [client]
    port            = 3307
    socket          = /data/mysql3307/mysql.sock
    
    [mysql]
    no-auto-rehash
    
    [mysqld]
    secure_file_priv = 
    user    = mysql
    port    = 3307
    socket  = /data/mysql3307/mysql.sock
    basedir = /usr/local/mysql
    datadir = /data/mysql3307/data
    open_files_limit    = 1024
    back_log = 600
    max_connections = 800
    max_connect_errors = 3000
    table_open_cache = 614
    external-locking = FALSE
    max_allowed_packet =8M
    sort_buffer_size = 1M
    join_buffer_size = 1M
    thread_cache_size = 100
    query_cache_size = 2M
    query_cache_limit = 1M
    query_cache_min_res_unit = 2k
    thread_stack = 192K
    tmp_table_size = 2M
    max_heap_table_size = 2M
    pid-file = /data/mysql3307/mysql.pid
    log-bin = /data/mysql3307/mysql-bin
    relay-log = /data/mysql3307/relay-bin
    relay-log-info-file = /data/mysql3307/relay-log.info
    binlog_cache_size = 1M
    max_binlog_cache_size = 1M
    max_binlog_size = 2M
    expire_logs_days = 7
    key_buffer_size = 16M
    read_buffer_size = 1M
    read_rnd_buffer_size = 1M
    bulk_insert_buffer_size = 1M
    lower_case_table_names = 1
    skip-name-resolve
    slave-skip-errors = 1032,1062
    replicate-ignore-db=mysql
    server-id = 6
    innodb_buffer_pool_size = 32M
    innodb_data_file_path = ibdata1:128M:autoextend
    innodb_thread_concurrency = 8
    innodb_flush_log_at_trx_commit = 2
    innodb_log_buffer_size = 2M
    innodb_log_file_size = 4M
    innodb_log_files_in_group = 3
    innodb_max_dirty_pages_pct = 90
    innodb_lock_wait_timeout = 120
    innodb_file_per_table = 0
    [mysqldump]
    quick
    max_allowed_packet = 2M
    
    [mysqld_safe]
    log-error=/data/mysql3307/mysql_3307.err
    pid-file=/data/mysql3307/mysqld.pid

    3、创建用户并授权

    # useradd -s /sbin/nologin -M mysql
    # chown -R mysql.mysql /data/mysql330*

    4、初始化

    # cd /mysql-path/bin      #进入到你的mysql安装路径
    # ./mysqld --defaults-file=/data/mysql3307/my.cnf --basedir=/usr/local/mysql --user=mysql --initialize-insecure --explicit_defaults_for_timestamp
    # echo $?             #确认初始化是否成功,返回0则成功

    5、启动多实例

    # cd /mysql-path/bin           #mysql的安装路径
    # ./mysqld_safe --defaults-file=/data/mysql3307/my.cnf &          #启动mysql

    6、确认进程

    # ps -ef|grep /data/mysql3307         #查看进程
    root     11893  7522  0 16:19 pts/3    00:00:00 /bin/sh ./mysqld_safe --defaults-file=/data/mysql3307/my.cnf
    mysql    12562 11893  0 16:19 pts/3    00:00:01 /usr/local/mysql/bin/mysqld --defaults-file=/data/mysql3307/my.cnf --basedir=/usr/local/mysql --datadir=/data/mysql3307/data --plugin-dir=/usr/local/mysql/lib/plugin --user=mysql --log-error=/data/mysql3307/mysql_3307.err --open-files-limit=1024 --pid-file=/data/mysql3307/mysqld.pid --socket=/data/mysql3307/mysql.sock --port=3307
    root     12926  7522  0 16:46 pts/3    00:00:00 grep --color=auto /data/mysql3307
    # netstat -lnutp|grep 3307            #查看端口
    tcp6       0      0 :::3307                 :::*                    LISTEN      12562/mysqld

    至此3307的多实例就配置完成了!!

    3308的配置和3307一样,但是需要修改配置文件

  • 相关阅读:
    rac node1节点侦听地址为127.0.0.1问题
    rac crs节点故障(未解决)
    杂牌设备网络接入引起交换机引起端口翻转的故障
    Impdp导出前准备工作以及主要命令
    查询dba_tables视图tablespaces_name为空的问题
    Expdp导出前准备工作以及主要命令
    带参数的方法解析
    类的无参方法,注释
    类和对象的解析
    二重循环的解析
  • 原文地址:https://www.cnblogs.com/hei-ma/p/9549322.html