• 锐捷交换机18010-X端口假死现象


    一次上架锐捷交换机,由于ODF光衰不稳定,导致交换机端口down,排查很多发现以下故障:
    重置18010-X端口发现提示一下命令:
    Port in violation! Use 'errdisable recovery' command to up the port!
     
     
    gz-sprine1#show interfaces tenGigabitEthernet 4/5 status
    Interface Status Vlan Duplex Speed Type
    ---------------------------------------- -------- ---- ------- --------- ------
    TenGigabitEthernet 4/5 disabled routed Unknown Unknown fiber
     
    修改 err为30s: errdisable recovery interval 30
    恢复出错的端口:errdisable recovery cause link-state
     
    重新检查交换机的状态,恢复正常。
    gz-sprine1#show interfaces tenGigabitEthernet 4/5 st
    gz-sprine1#show interfaces tenGigabitEthernet 4/5 status
    Interface Status Vlan Duplex Speed Type
    ---------------------------------------- -------- ---- ------- --------- ------
    TenGigabitEthernet 4/5 down routed Unknown Unknown fiber
    gz-sprine1#
     
    备注:端口处于error状态,端口不会发光,技术上称为假死。