    The ScaleIO virtual SAN consists of 3 software components

    ===================

    Meta Data Manager (MDM):
    Configures and monitors the ScaleIO system. The MDM can be configured in a redundant Cluster Mode with three members on three servers or in a Single Mode on a single server.

    An MDM cluster consists of three components:

    • Primary MDM
    • Secondary MDM
    • Tie-Breaker

     

    ScaleIO Data Server (SDS):
    Manages the capacity of a single server and acts as a backend for data access. The SDS is installed on all servers contributing storage devices to the ScaleIO system. These devices are accessed through the SDS.

     

    ScaleIO Data Client (SDC):
    A lightweight device driver that exposes ScaleIO volumes as block devices to the application residing on the same server on which the SDC is installed.

     

    image

    Figure 1. ScaleIO architecture

     

    Storage Definitions

    ===================

    Protection Domain:

    A Protection Domain is a subset of SDSs. Each SDS belongs to one (and only one) Protection Domain. Thus, by definition, each Protection Domain is a unique set of SDSs.

     

    Storage Pool
    A Storage Pool is a subset of physical storage devices in a Protection Domain. Each storage device belongs to one (and only one) Storage Pool. When a Protection Domain is generated, by default it has one Storage Pool (Default).

    When a volume is configured over the virtualization layer the volume is distributed over all devices residing in the same Storage Pool. This allows more than one failure in the system without losing data. Since a Storage Pool can withstand the loss of one of its members, having two failures in two different Storage Pools will not cause data loss.

    image

     

    Storage Tiers

    Storage Pools allow the generation of different storage tiers in the ScaleIO system. When generating a Protection Domain, it is recommended to have SDSs which have the same storage media associated with them (though usually that is the case in most
    datacenters since the servers are commonly cloned).

    The same goes for a Storage Pool. The best practice would be having the same storage devices in the same pool. This ensures that the volumes will be distributed over the same type of storage.

    Note: Mixing different types of media in the same pool is allowed, but one should be aware that due to the distribution of the data, performance will be as good as the least-performing member of the Storage Pool.

    ScaleIO Physical Layer

    ========================

    1. MDM. 3 nodes for a redundant management cluster in Cluster MDM, or a single node in case of a Single MDM.

    2. SDS. Identify all the nodes which will contribute some, or all, of their physical storage. Install an SDS component on them. Divide the SDSs (nodes) into Protection Domains. Each SDS can be a member of only one Protection Domain. Divide the SDSs (nodes) into Protection Domains. Each SDS can be a member of only one Protection Domain.

    3. Identify all the nodes on which the application will access the data exposed by the ScaleIO volumes. Install an SDC component on them. As for communication, the system utilizes the already existing LAN. The components communicate over the LAN using standard TCP/IP. The SDS may have multiple IP addresses, allowing wider bandwidth and better IO performance and redundancy.

    As for communication, the system utilizes the already existing LAN. The components communicate over the LAN using standard TCP/IP. The SDS may have multiple IP addresses, allowing wider bandwidth and better IO performance and redundancy.

     

    ScaleIO Virutalization Layer

    =======================

    In this layer, users can:

    • Define volumes.
    • Map volumes

     

    ScaleIO over VMware

    =======================

    In a VMware environment, ScaleIO provides a ScaleIO SCSI target. This target is enclosed, as all the other components, in a virtual machine (VM) that is specific to ScaleIO, known as ScaleIOVM. The ScaleIO SCSI target exposes LUNs to the hypervisor's SCSI initiator. These LUNs are in-turn used by other virtual machines through the data-store.

    image

    Figure 3 ScaleIO VM architecture

     

    参考资料

    ========================

    EMC ScaleIO User Guide v1.20.1 for Linux and VMware

    https://support.emc.com/docu50195_ScaleIO-User-Guide-1.20.1.pdf

  • 相关阅读:
    自定义UITableViewCell
    使用NSOperation实现异步下载
    iOS中判断一个文件夹是否存在
    iphone下载进度条,显示下载字节数与百分比
    NSURLConnection下载文件并显示进度(HEAD)
    iphone 模拟器 显示 隐藏的资源库
    iOS使用NSURLConnection发送同步和异步HTTP Request
    NSFileManager和NSFileHandle(附:获取文件大小 )
    xcode4.2设立Created by &MyCompanyName_
    iphone开发之轻松搞定原生socket 编程,阻塞与非阻塞,收发自如
  • 原文地址:https://www.cnblogs.com/awpatp/p/3809877.html
Copyright © 2020-2023  润新知