Symptom:
Unable to SSH/HTTP to the CIMC of the C-series server, however the CIMC can be pinged. Also will notice the fans in the server running at a higher rate.
Generic OS installed on the server is not affected. Only out-of-band management.
===================================
Addendum:
If the affected device is an APIC running 1.0(4q) and higher, this may cause an issue where the APIC software is unable to read system-product-name and system-serial-number from SPROM. . This is sometimes seen during a planned upgrade from versions before 1.0(4q) to versions higher than 1.0(4q).
Conditions:
The timing of this can be variable, but it has been seen to occur after approximately 60 days.
Workaround:
AC power cycle the server, as in, physically removing all power from the server.
Further Problem Description:
Product: |
(1)
|
Known Affected Releases: |
(5)
|
Known Fixed Releases: |
(4)
|