• Oracle RAC CSS 超时计算 及 参数 misscount, Disktimeout 说明


    一. 概述

    在之前的文章:

           RAC 的一些概念性和原理性的知识

           http://blog.csdn.net/tianlesoftware/article/details/5331067

          

           提到OCSSD 这个进程是Clusterware最关键的进程,如果这个进程出现异常,会导致系统重启,这个进程提供CSS(Cluster Synchronization Service)服务。 CSS 服务通过多种心跳机制实时监控集群状态,提供脑裂保护等基础集群服务功能。

           CSS 服务有2种心跳机制: 一种是通过私有网络的Network Heartbeat,另一种是通过Voting Disk的Disk Heartbeat.

           这2种心跳都有最大延时,对于Disk Heartbeat, 这个延时叫作IOT (I/O Timeout);对于Network Heartbeat, 这个延时叫MC(Misscount)。 这2个参数都以秒为单位,缺省时IOT大于MC,在默认情况下,这2个参数是Oracle 自动判定的,并且不建议调整。

    可以通过如下命令来查看参数值:

    $crsctl get css disktimeout

    $crsctl get css misscount

    如:

    [oracle@rac1 ~]$ crsctl get css disktimeout

    200

    [oracle@rac1 ~]$ crsctl get css misscount

    60

    这是这2个参数的默认值。

    二. MOS 上相关的几篇文章

    How to start/stop the 10g CRS ClusterWare[ID 309542.1]

    10g RAC: Steps To Increase CSS Misscount,Reboottime and Disktimeout [ID 284752.1]

    CSS Timeout Computation in OracleClusterware [ID 294430.1]

    RAC Assurance Support Team: RAC and OracleClusterware Starter Kit and Best Practices (Generic) [ID 810394.1]

    2.1修改CSS Misscount 步骤:

      1)Shut down CRS on all but one node. For exact steps use Note 309542.1

      2)Execute crsctl as root to modify the misscount:

        $ORA_CRS_HOME/bin/crsctl set css misscount <n>

        where <n> is the maximum i/o latency to the voting disk +1 second

      3)Reboot the node where adjustment was made

      4)Start all other nodes shutdown in step 1

    With the Patch:4896338 for 10.2.0.1 thereare two additional settings that can be tuned. This change is incorporated into the 10.2.0.2 and 10.1.0.6patchsets.  

     

     

    These following are only relevant on10.2.0.1 with Patch:4896338,In addition to MissCount, CSS now has two more parameters:

      1)reboottime (default 3 seconds) - the amount of time allowed for a node  to complete a reboot after the CSS daemon hasbeen evicted. (I.E. how  long does ittake for the machine to completely shutdown when you do a reboot)

      2)disktimeout (default 200 seconds) - the maximum amount of time allowed      for a voting file I/O to complete; if thistime is exceeded the voting disk will be marked as offline.  Note that this is also the amount of timethat will be required for initial cluster formation, i.e. when no nodes havepreviously been up and in a cluster.

          $CRS_HOME/bin/crsctl set css reboottime <r> [-force]  (<r> is seconds)

          $CRS_HOME/bin/crsctl set css disktimeout <d> [-force] (<d>is seconds)

    Confirm the new css  misscount setting via ocrdump

    2.2 CSS Timeout Computation in OracleClusterware

    2.2.1 MISSCOUNTDEFINITION AND DEFAULT VALUES
           The CSS misscount parameterrepresents the maximum time, in seconds, that a network heartbeat can be missedbefore entering into a cluster reconfiguration to evict the node. The followingare the default values for the misscount parameter and their respectiveversions when using Oracle Clusterware* in seconds:

    OS

    10g (R1 &R2)

    11g

    Linux

    60

    30

    Unix

    30

    30

    VMS

    30

    30

    Windows

    30

    30

           *CSS misscount default value when using vendor (non-Oracle)clusterware is 600 seconds. This is to allow the vendor clusterwareample time to resolve any possible split brain scenarios.

           On AIX platforms with HACMP starting with 10.2.0.3 BP#1, themisscount is 30. This is documented in Note551658.1

    2.2.2 CSS HEARTBEATMECHANISMS AND THEIR INTERRELATIONSHIP
           The synchronization servicescomponent (CSS) of the Oracle Clusterware maintains two heartbeat mechanisms

    1.) the disk heartbeat to the voting deviceand

    2.) the network heartbeat  across theinterconnect which establish and confirm valid node membership in the cluster.

           Bothof these heartbeat mechanisms have an associated timeout value. The diskheartbeat has an internal i/o timeout interval (DTO Disk TimeOut), in seconds,where an i/o to the voting disk must complete. The misscount parameter (MC), asstated above, is the maximum time, in seconds, that a network heartbeat can be missed. The disk heartbeat i/o timeout interval is directly related tothe misscount parameter setting. There has been some variation in thisrelationship 
    between versions as described below:

    9.x.x.x

    NOTE, MISSCOUNT WAS A  DIFFERENT ENTITY IN THIS RELEASE

    10.1.0.2

    No one should be on this version

    10.1.0.3

    DTO = MC - 15 seconds

    10.1.0.4

    DTO = MC - 15 seconds

    10.1.0.4+Unpublished Bug 3306964

    DTO = MC - 3 seconds

    10.1.0.4 with CRS II Merge patch

    DTO =Disktimeout (Defaults to 200 seconds) Normally OR Misscount seconds only during initial Cluster formation or Slightly before reconfiguration

    10.1.0.5

    IOT = MC - 3 seconds

    10.2.0.1 +Fix for unpublished Bug 4896338

    IOT=Disktimeout (Defaults to 200 seconds) Normally OR Misscount seconds only during initial Cluster formation or Slightly before reconfiguration

    10.2.0.2

    Same as above (10.2.0.1 with Patch Bug:4896338

    10.1 - 11.1

    During node join and leave (reconfiguration) in a cluster we need to reconfigure, in that particular case we use Short Disk TimeOut (SDTO) which is in all versions SDTO = MC – reboottime (usually 3 seconds) 

           Misscountdrives cluster membership reconfigurations and directly effects theavailability of the cluster. In most cases, the default settings for MC shouldbe acceptable.  Modifying the default value of misscount not onlyinfluences the timeout interval for the i/o to the voting disk, but alsoinfluences the tolerance for missed network heartbeats across the interconnect.

    2.2.3 LONG LATENCIES TOTHE VOTING DISKS
           If I/O latencies to the voting diskare greater than the default DTO calculations noted above, the cluster mayexperience CSS node evictions depending on (a)the Oracle Clusterware (CRS)version, (b)whether merge patch has been applied and (c)the state of theCluster. More details on this are covered in the section "Change inBehavior with CRS Merge PATCH (4896338 on 10.2.0.1)".

           Theselatencies can be attributed to any number of problems in the i/o subsystem orproblems with any component in the i/o path. The following is a non exhaustivelist of reported problems which resulted in CSS node eviction due to latenciesto the voting disk longer than the default Oracle Clusterware i/o timeoutvalue(DTO):

    1.       QLogic HBA cards with a LinkDown Timeout greater than the default misscount.

    2.       Bad cables to the SAN/storagearray that effect i/o latencies

    3.       SAN switch (like Brocade)failover latency greater than the default misscount

    4.       EMC Clariion Array whentrespassing the SP to the backup SP greater than default misscount

    5.       EMC PowerPath path errordetection and I/O repost and redirect greater than defaultmisscount  

    6.       NetApp Cluster (CFO) failoverlatency greater than default misscount

    7.       Sustained high CPU load whicheffects the CSSD disk ping monitoring thread

    8.       Poor SAN network configurationthat creates latencies in the I/O path.


           The mostcommon problems relate to multi-path IO software drivers, and thereconfiguration times resulting from a failure in the IO path. Hardwareand (re)configuration issues that introduce these latencies should becorrected. Incompatible failover times with underlying OS, network or storagehardware or software may be addressed given a complete understanding of theconsiderations listed below.

           Misscount should NOT be modified to workaround theabove-mentioned issues. Oracle support recommends that you apply thelatest patchset which changes the CSS behaviour. More details covered innext section.

    2.2.4 Change in Behaviorwith Bug:4896338 applied on top of 10.2.0.1
           Starting with 10.2.0.1+Bug:4896338,CSS will not evict the node from the cluster due to (DTO) I/O to voting disktaking more than misscount seconds unless it is during the initial clusterformation or slightly before reconfiguration. 
           So if we have a N number ofnodes in a cluster and one of the nodes takes more than misscountseconds to access the voting disk, the node will not be evicted as long asthe access to the voting disk is completed within disktimeoutseconds. Consequently with this patch, there is no need to increasethe misscount at all.

           Additionallythis merge patch introduces Disktimeout  which is the amount of time thata lack of disk ping to voting disk(s) will be tolerated.

    Note:  applying the patch will notchange your value for Misscount.  

    The table below explains inthe conditions under which the eviction will occur

    Network Ping

    Disk Ping

    Reboot

    Completes within misscount seconds

    Completes within Misscount seconds

    N

    Completes within Misscount seconds

    Takes more than misscount seconds but less than Disktimeout seconds

    N

    Completes within Misscount seconds

    Takes more than Disktimeout seconds

    Y

    Takes more than Misscount Seconds

    Completes within Misscount seconds

    Y

     * By default Misscount is lessthan Disktimeout seconds

    2.2.5 CONSIDERATIONS WHENCHANGING MISSCOUNT FROM THE DEFAULT VALUE

    1.       Customers drive SLA and clusteravailability. The customer ultimately defines Service Levels and availabilityfor the cluster. Before recommending any change to misscount, the full impactof that change should be described and the impact to cluster availabilitymeasured.

    2.       Customers may have timeout andretry logic in their applications. The impact of delaying reconfiguration maycause 'artificial' timeouts of the application, reconnect failures andsubsequent logon storms.

    3.       Misscount timeout values areversion dependent and are subject to change. As we have seen, misscountcalculations are variable between releases and between versions within arelease. Creating a false dependency on misscount calculation in one versionmay not be appropriate for later versions.

    4.       Internal I/O timeout interval(DTO) algorithms may change in later releases as stated above, there exists adirect relationship between the internal I/O timeout interval and misscount.This relationship is subject to change in later releases.

    5.       An increase in misscount tocompensate for i/o latencies directly effects reconfiguration times for networkfailures. The network heartbeat is the primary indicator of connectivity withinthe cluster. Misscount is the tolerance level of missed 'check ins' thattrigger cluster reconfiguration. Increasing misscount will prolong the time totake corrective action in the event of network failure or other anomalieseffecting the availability of a node in the cluster. This directly effectscluster availability.

    6.       Changing misscount toworkaround voting disk latencies will need to be corrected when the underlyingdisk latency is corrected, misscount needs to be set back to the default Thecustomer needs to document the change and set the parameter back to the defaultwhen the underlying storage I/O latency is resolved.

    7.       Do not change default misscountvalues if you are  running Vendor Clusterware along with OracleClusterware. The default values for misscount should not be changed when usingvendor clusterware. Modifying misscount in this environment may causeclusterwide outages and potential corruptions.

    8.       Changing misscount parameterincurs a clusterwide outage. As note below, the customer will need to schedule 
    a clusterwide outage to make this change.

    9.       Changing misscount should notbe used to compensate for poor configurations or faulty hardware

    10.   Cluster and RDBMS availabilityare directly effected by high misscount settings.

    11.   In case of stretched clustersand stretched storage systems and a site failure where we loose one storage andN number of nodes we go into a reconfiguration state and then we revert toShortDiskTimeOut value as internal I/O timeout for the votings. Several casesare known with stretched clusters where when a site failure happen the storagefailover cannot complete within SDTO. If the I/O to the votings is blocked morethan SDTO the result is node evictions on the surviving side. 


    To Change MISSCOUNT back to default Please referto Note:284752.1
           THIS IS THE ONLY SUPPORTED METHOD.NOT FOLLOWING THIS METHOD RISKS EVICTIONS AND/OR CORRUPTING THE OCR

    10g Release 2 MIRRORED VOTING DISKS AND VENDORMULTIPATHING SOLUTIONS 
           Oracle RAC 10g Release 2 allows formultiple voting disks so that  the customer does not have to rely on amultipathing solution from a storage vendor. You can have n voting disks (up to31) where n = m*2+1 where m is the number of disk failures you  want tosurvive. Oracle recommends each voting disk to be on a separate physical disk.

    -------------------------------------------------------------------------------------------------------

    Blog:http://blog.csdn.net/tianlesoftware

    Weibo: http://weibo.com/tianlesoftware

    Email: dvd.dba@gmail.com

    DBA1 群:62697716(满);   DBA2 群:62697977(满)  DBA3 群:62697850(满)  

    DBA 超级群:63306533(满);  DBA4 群: 83829929(满) DBA5群: 142216823(满) 

    DBA6 群:158654907(满)  聊天 群:40132017(满)   聊天2群:69087192(满)

    --加群需要在备注说明Oracle表空间和数据文件的关系,否则拒绝申请

  • 相关阅读:
    react 组件传值
    vue 子组件如何修改父组件data中的值??????????????????
    移动端的一些初始化 css 样式。。。
    centos7命令
    poi导出
    eclipse项目导入工作空间提示已存在问题
    maven jar包冲突问题
    layui下拉框渲染问题,以及回显问题
    两个线程交替运行——使用synchronized+wait+notify实现
    造成索引失效的情况
  • 原文地址:https://www.cnblogs.com/tianlesoftware/p/3609583.html
Copyright © 2020-2023  润新知