一、下载Magent
官网:https://code.google.com/archive/p/memagent/downloads
离线版本:(链接: https://pan.baidu.com/s/1kU9DLI3 密码: k6qg)
二、编译安装
说明:magent由于是10年的产品,所以编译时一定会报错,但是先不要按照网上的修改来操作,应该先执行make,然后看错误来解决,因为每个系统的解决方式都不同,应该按照不同的系统来处理才是最优的解法。
前提:先安装Memcached,参考:http://www.cnblogs.com/EasonJim/p/7572264.html
解压:
mkdir magent tar -zxvf magent-0.6.tar.gz -C magent sudo mv magent /usr/local
cd /usr/local/magent
编译:
1、在ketama.h文件开头添加
#ifndef SSIZE_MAX
#define SSIZE_MAX 32767
#endif
2、修改Makefile文件
ARCH := $(shell uname -m) X64 = x86_64 CC = gcc PROGS = magent ifeq ($(ARCH), $(X64)) M64 = -m64 LIBS = /usr/local/lib/libevent.a /usr/lib/x86_64-linux-gnu/libm.so else LIBS = -levent -lm -L/usr/local/lib endif CFLAGS = -Wall -g -O2 -I/usr/local/include $(M64) all: $(PROGS) STPROG = magent.o ketama.o ketama.o: ketama.c ketama.h $(CC) $(CFLAGS) -c -o $@ ketama.c magent.o: magent.c ketama.h $(CC) $(CFLAGS) -c -o $@ magent.c magent: $(STPROG) $(CC) $(CFLAGS) -o $@ $^ $(LIBS) clean: rm -f *.o *~ $(PROGS)
说明:标红部分修改即可。
3、make编译成功
三、部署方案及说明
当网站访问量达到一定时,如何做Memcached集群,又如何高可用,是接下来要讨论的问题。
有这么一段文字来描述“Memcached集群”
Memcached如何处理容错的?
不处理!:) 在memcached节点失效的情况下,集群没有必要做任何容错处理。如果发生了节点失效,应对的措施完全取决于用户。节点失效时,下面列出几种方案供您选择:
* 忽略它! 在失效节点被恢复或替换之前,还有很多其他节点可以应对节点失效带来的影响。
* 把失效的节点从节点列表中移除。做这个操作千万要小心!在默认情况下(余数式哈希算法),客户端添加或移除节点,会导致所有的缓存数据不可用!因为哈希参照的节点列表变化了,大部分key会因为哈希值的改变而被映射到(与原来)不同的节点上。
* 启动热备节点,接管失效节点所占用的IP。这样可以防止哈希紊乱(hashing chaos)。
根据上面的说法,Memcached其中一个节点失效以后,Memcached本身是没有任何策略维持失效转发的,这对于大型系统是一个无法接受的事实。
举例说明:
在客户端连接的部分写入多个服务器端的ip地址,客户端将会自动的把缓存数据分布的放在每个不同的机器上,如图所示:
缺陷说明:
如果其中一个缓存节点的机器down机,那么客户端存入的缓存数据将会丢失一部分,就是图中红色字体描述的“Losed 33% Cache Data”,也就是说那部分数据彻底没有了!如果是用户的关键性信息那么就玩大了,如图所示:
解决方案:采用缓存代理服务器
采用Magent缓存代理,防止单点现象,缓存代理也可以做备份,通过客户端连接到缓存代理服务器,缓存代理服务器连接缓存服务器,缓存代理服务器可以连接多台Memcached机器,如下图所示,配件清单如下:
Magent代理服务器:2台,分别为 192.168.1.2:12000、192.168.1.3:12000
Memcached主服务器:3台,分别为 192.168.1.4:11211、192.168.1.5:11211、192.168.1.6:11211
Memcached备服务器:2台,分别为 192.168.1.5:11211、192.168.1.6:11211
搭建Memcahced服务器:
在 192.168.1.4、192.168.1.5、192.168.1.6、192.168.1.7、192.168.1.8 上分别编译安装并运行Memcached
搭建Magent代理服务器:
在 192.168.1.2、192.168.1.3上分别编译安装magent
magent命令详解(使用Google来翻译):
-h this message
-u uid
-g gid
-p port, default is 11211. (0 to disable tcp support)
-s ip:port, set memcached server ip and port
-b ip:port, set backup memcached server ip and port
-l ip, local bind ip address, default is 0.0.0.0
-n number, set max connections, default is 4096
-D do not go to background
-k use ketama key allocation algorithm
-f file, unix socket path to listen on. default is off
-i number, max keep alive connections for one memcached server, default is 20
-v verbose
在 192.168.1.2、192.168.1.3 上分别运行magent:
magent -u root -n 51200 -l 192.168.1.2 -p 12000 -s 192.168.1.4:11211 -s 192.168.1.5:11211 -s 192.168.1.6:11211 -b 192.168.1.7:11211 -b 192.168.1.8:11211
说明:常用两项-s为主节点,-b为备用节点。
测试缓存数据的分布情况说明:
1、Java连接magent,把缓存key1交给magent,magent根据自身的配置参数,再加上一定的哈希算法,会计算出key1存在3台主Memcached服务器的某一台上,然后以同样的算法,将key1也在2台备用的Memcached服务器中的某一台上,再存一份数据。即,主服务器是分布式存储的,同时,从服务器也是分布式存储的;
2、在Java获取缓存数据key1时,magent一旦得知数据所存的那台主Memcached服务器挂掉了,它就会转向从备用的Memcached服务器中获取数据。注意:服务器的定位选择算法跟存的时候是一样的。
3、有个缺陷,当down掉的那台主Memcached服务器重新恢复正常后,Memcahed里是没有数据的,即数据全部丢失,但此时备用的Memcached服务器又不会将数据同步到 主服务器。
4、通过Memcached管理软件MemAdmin(点击下载)去查看上述数据分布情况,如下:
192.168.1.4 存有 snsgou6,snsgou3
192.168.1.5 存有 snsgou4,snsgou1
192.168.1.6 存有 snsgou5,snsgou2
192.168.1.7 存有 snsgou5,snsgou3,snsgou1
192.168.1.8 存有 snsgou4,snsgou6,snsgou2
5、Java连接代理的时候,最好每次随机性只连一台,这样,一旦某台代理挂了(即连不上),可切换连另外一台代理服务器。而随机性地去连,又保证了一定的负载均衡。
四、测试实例:
#启动magent实例
/usr/local/magent/magent -u root -n 4096 -l 192.168.11.51 -p 11200 -s 192.168.11.51:11211 -s 192.168.11.52:11211 -b 192.168.11.68:11211
/usr/local/magent/magent -u root -n 4096 -l 192.168.11.52 -p 11200 -s 192.168.11.51:11211 -s 192.168.11.52:11211 -b 192.168.11.68:11211
1、登录51上的magent,存储key1到key5:
telnet 192.168.11.51 11200 Trying 192.168.11.51... Connected to 192.168.11.51. Escape character is '^]'. stats memcached agent v0.4 matrix 1 -> 192.168.11.51:11211, pool size 0 matrix 2 -> 192.168.11.52:11211, pool size 0 END set key1 0 0 1 1 STORED set key2 0 0 2 22 STORED set key3 0 0 3 333 STORED set key4 0 0 4 4444 STORED set key5 0 0 5 55555 STORED quit Connection closed by foreign host.
登录到51上的Memcached,获取到了key2和key4:
telnet 192.168.11.51 11211 Trying 192.168.11.51... Connected to 192.168.11.51. Escape character is '^]'. get key1 END get key2 VALUE key2 0 2 22 END get key3 END get key4 VALUE key4 0 4 4444 END get key5 END quit Connection closed by foreign host.
登录到52上的Memcached,获取到了key1、key3和key5:
telnet 192.168.11.52 11211 Trying 192.168.11.52... Connected to 192.168.11.52. Escape character is '^]'. get key1 VALUE key1 0 1 1 END get key2 END get key3 VALUE key3 0 3 333 END get key4 END get key5 VALUE key5 0 5 55555 END quit Connection closed by foreign host.
登录到68上的Memcached,获取到了key1到key5:
telnet 192.168.11.68 11211 Trying 192.168.11.68... Connected to 192.168.11.68. Escape character is '^]'. get key1 VALUE key1 0 1 1 END get key2 VALUE key2 0 2 22 END get key3 VALUE key3 0 3 333 END get key4 VALUE key4 0 4 4444 END get key5 VALUE key5 0 5 55555 END quit Connection closed by foreign host.
停掉52的Memcached进程,通过51上的magent获取到了key1到key5:
kill `cat /var/run/memcached/memcached.pid`
telnet 192.168.11.51 11200 Trying 192.168.11.51... Connected to 192.168.11.51. Escape character is '^]'. get key1 VALUE key1 0 1 1 END get key2 VALUE key2 0 2 22 END get key3 VALUE key3 0 3 333 END get key4 VALUE key4 0 4 4444 END get key5 VALUE key5 0 5 55555 END quit Connection closed by foreign host.
恢复52的Memcached进程,通过51上的magent,只获取到了key2和key4:
telnet 192.168.11.51 11200 Trying 192.168.11.51... Connected to 192.168.11.51. Escape character is '^]'. get key1 END get key2 VALUE key2 0 2 22 END get key3 END get key4 VALUE key4 0 4 4444 END get key5 END quit Connection closed by foreign host.
通过以上测试可以得出结论:
1. 通过magent的连接池存放的值会分别存在magent代理的所有Memcached上去。
2. 如果有一个Memcached宕机通过magent代理方式还能取到值。
3. 如果Memcached修复重启后通过magent代理方式取到的值就会为Null,这是由于Memcache重启后里边的值随着Memcache服务的停止就消失了(因为在内存中),但是magent是通过key进行哈希计算分配到某台机器上的,Memcache重启后会还从这台机器上取值,所有取到的值就为空。
解决办法:
1. 在每次Memcache宕机修复后可以写一个程序把集群中的其他Memcache的所有信息全给拷贝到当前宕机修复后的Memcache中。
2. 自己写代理,当从一个Memcached服务上取到的值为Null时再去其他Memcached上取值。
注意事项:
magent的调用方式同Memcached一样,客户端可以不用改代码即可实现切换到magent模式下。
五、缓存与DB的同步的方法:
比较保险的做法是:查询的时候从缓存中取,add、updae、delete的时候同时操作缓存与DB。
当然你也可以定时同步缓存与DB的数据,不同的业务应该有不同的选择。
参考:
http://kb.cnblogs.com/page/69074/
http://carvin.iteye.com/blog/825070
http://ultrasql.blog.51cto.com/9591438/1636374/(解决在Ubuntu编译Magent的问题)
http://xiemingmei.iteye.com/blog/1418291
https://www.2cto.com/database/201702/595692.html
http://www.iteye.com/topic/1129147
http://www.iteye.com/topic/1128229
http://www.cnblogs.com/52php/p/5675711.html(以上大部分内容转自此篇文章)
http://blog.csdn.net/cutesource/article/details/5848253
http://tim-fly.iteye.com/blog/1764519
http://www.cnblogs.com/zhangrumingbj/p/3887683.html
http://kaibinyuan.blog.51cto.com/7304008/1612364
http://www.cnblogs.com/szuyuan/p/4866891.html
http://tim-fly.iteye.com/blog/1756936
http://blog.csdn.net/haozhongjun/article/details/52936695